Changes for page Crestron Zūm Wired

Last modified by Scott Kohlmann on 2023/04/20 22:22

From version 12.1
edited by Mark Kohlmann
on 2021/05/06 15:19
Change comment: There is no comment for this version
To version 19.1
edited by Scott Kohlmann
on 2023/04/20 22:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome
1 +Design Guide.Hardware Design Guide.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.mark\.kohlmann@chiefintegrations\.com
1 +XWiki.scott\.kohlmann@chiefintegrations\.com
Hidden
... ... @@ -1,1 +1,1 @@
1 -false
1 +true
Content
... ... @@ -1,15 +1,15 @@
1 - Crestron Zūm Wired is a locally integrated lighting control system with various global control options.  Zūm rooms are self-contained control units with primary logic occurring at the room level.  Central control systems offer scheduling and management.  SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design.
1 +Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management.  ShowRunnerCLC™ provides a number of integrations options that allow the designer to optimize the solution design.
2 2  
3 3  ~*~*~* Specifications are preliminary, the Zūm wired ZUM-FLOOR-HUB has not been released ~*~**
4 4  
5 5  ==== Integration Options ====
6 6  
7 -* **SHOWRUNNER™ Total Control** - The most comprehensive option.  Allows seamless integration of Zūm and non-Zūm Crestron lighting control products.  Extensive feature set allows centralized control and management of Zūm rooms.  Advanced scheduler provides more flexibility to the facility operator.  This solution replaces the ZUM-FLOOR-HUB in the system design.
8 -* **SHOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub.  SHOWRUNNER™ can export its own areas to the Floor Hub.
7 +* **ShowRunnerCLC™ Total Control** - The most comprehensive option.  Allows seamless integration of Zūm and non-Zūm Crestron lighting control products.  Extensive feature set allows centralized control and management of Zūm rooms.  Advanced scheduler provides more flexibility to the facility operator.  This solution replaces the ZUM-FLOOR-HUB in the system design.
8 +* **ShowRunnerCLC™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub.  ShowRunnerCLC™ can export its own areas to the Floor Hub.
9 9  
10 10  ==== Feature Matrix ====
11 11  
12 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
12 +|=Feature|=ShowRunnerCLC™ Total Control|=ShowRunnerCLC™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App*
13 13  |(% colspan="5" %)**Hardware Requirements**
14 14  |Requires ZUMNET JBox|Y|Y|Y|N
15 15  |Requires 3 or 4-Series Control System|Y|Y|N|N/A
... ... @@ -19,9 +19,9 @@
19 19  |Web Browser|(((
20 20  Crestron SmartGraphics XPanel
21 21  HTML5 UI
22 -)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel
22 +)))|ShowRunnerCLC™ - Crestron SmartGraphics XPanel/HTML5 UI
23 23  ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N
24 -|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
24 +|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
25 25  |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N
26 26  |(% colspan="5" %)**Features**
27 27  |Scene Recall|Y|Y|Y|Y
... ... @@ -28,7 +28,7 @@
28 28  |Override Fade Time for Scene Recall|Y|TBD|TBD|TBD
29 29  |Scene Save|Y|TBD|TBD|Y
30 30  |Load Control|Y|TBD|TBD|Y
31 -|Demand Response|Y|Y, separate triggers for SHOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N
31 +|Demand Response|Y|Y, separate triggers for ShowRunnerCLC™ and ZUM-FLOOR-HUB required|Y|N
32 32  |Enable/Disable Occupancy|Y|Y, from Floor Hub|Y|Y
33 33  |Override Occupancy Logic|Y|TBD|TBD|N
34 34  |Override|Y|Scene Recall only via ShowRunner|TBD|N/A
... ... @@ -35,22 +35,22 @@
35 35  |Plug Load On/Off|Y|Y|Y|By Hardware
36 36  |Integration with Non-Zūm Crestron Hardware|Y|N|N|N
37 37  |Custom Zūm Keypad Programming|Y|TBD|TBD|Y, within the limits of the hardware
38 -|New Feature Release Cycle|Aggressive|SHOWRUNNER™: Aggressive
38 +|New Feature Release Cycle|Aggressive|ShowRunnerCLC™: Aggressive
39 39  Floor Hub: 6-12 months|6-12 months|6-12 months
40 40  |Room Organization|(((
41 41  Organize According to Defined Nodes, multiple levels
42 42  Categorization to Filter by Tag
43 -)))|SHOWRUNNER™: See SHOWRUNNER™ Total Control
43 +)))|ShowRunnerCLC™: See ShowRunnerCLC™ Total Control
44 44  Floor Hub: Category/Room|Category/Room|(((
45 45  N/A
46 46  )))
47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices|SHOWRUNNER™: Automatic discovery
48 -Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A
47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|ShowRunnerCLC™: Automatic discovery (Pending)
48 +Floor Hub: Map Mirrored Rooms to ShowRunnerCLC™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A
49 49  |Network Topology|(((
50 50  * Flat
51 51  * Single Handoff to LAN w/ Control Subnet
52 52  (Requires  CP4N/AV4/PRO4)
53 -)))|Single Handoff to LAN w/ Control Subnet.  ShowRunner can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A
53 +)))|Single Handoff to LAN w/ Control Subnet.  ShowRunnerCLC™ can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A
54 54  |Network Addressing|(((
55 55  * Manual
56 56  * Customer (DHCP or Manual)
... ... @@ -57,30 +57,30 @@
57 57  * DHCP: Control Subnet (Requires CP4N/AV4/PRO4)
58 58  )))|Control Subnet|Control Subnet|N/A
59 59  |Firmware Updates|PUF Tool
60 -Automatic Support on Roadmap|SHOWRUNNER™: PUF Tool
60 +Automatic Support on Roadmap|ShowRunnerCLC™: PUF Tool
61 61  Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A
62 -|Floorplans|Y|SHOWRUNNER™: Y
62 +|Floorplans|Y|ShowRunnerCLC™: Y
63 63  Floor Hub: N|N|N/A
64 64  |(% colspan="5" %)**Calendar/Scheduling**
65 65  |Logic Type|Event Driven
66 -Profile Support (Under Development)|SHOWRUNNER™: Event Driven
66 +Profile Support (Under Development)|ShowRunnerCLC™: Event Driven
67 67  Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A
68 68  |Astronomical Clock|Y|Y, Per Category|Y, Per Category|N/A
69 -|Holidays|Pattern|SHOWRUNNER™: Pattern
69 +|Holidays|Pattern|ShowRunnerCLC™: Pattern
70 70  Floor Hub: Hard Coded|Hard Coded|N/A
71 -|Custom Patterns|Y, Advanced Scheduler License|SHOWRUNNER™: Y, Advanced Scheduler License
71 +|Custom Patterns|Y, Advanced Scheduler License|ShowRunnerCLC™: Y, Advanced Scheduler License
72 72  Floor Hub: N|N|N/A
73 73  |(% colspan="5" %)**Integrations**
74 -|A/V Integration: API|Y|SHOWRUNNER™: Y
74 +|A/V Integration: API|Y|ShowRunnerCLC™: Y
75 75  Floor Hub: Limited|Limited|N/A
76 -|A/V Integration: Crestron EISC|Y|SHOWRUNNER™: Y
76 +|A/V Integration: Crestron EISC|Y|ShowRunnerCLC™: Y
77 77  Floor Hub: N|N|N/A
78 78  |A/V Integration: RS-232|Y|(((
79 -SHOWRUNNER™: Y
79 +ShowRunnerCLC™: Y
80 80  Floor Hub: TBD
81 81  )))|TBD|N/A
82 82  |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|(((
83 -SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed
83 +ShowRunnerCLC™: ShowRunnerCLC™ and Crestron Licenses Needed
84 84  Floor Hub: Y
85 85  )))|Y|N/A
86 86  |BACNET Features|(((
... ... @@ -98,7 +98,7 @@
98 98  
99 99  ~* More Features added upon request
100 100  )))|(((
101 -SHOWRUNNER™: See list for SHOWRUNNER™ Total Control
101 +ShowRunnerCLC™: See list for ShowRunnerCLC™ Total Control
102 102  Floor Hub: See list for ZUM-FLOOR-HUB
103 103  )))|(((
104 104  Per Room Status:
... ... @@ -116,24 +116,35 @@
116 116  )))|N/A
117 117  |BACNET Settings Scope
118 118  (What Points are Exposed)|Per Area|(((
119 -SHOWRUNNER™: Per Area
119 +ShowRunnerCLC™: Per Area
120 120  Floor Hub: Global
121 121  )))|Global|N/A
122 -|BACNET Points Supported|Depends on Crestron License and Hardware|SHOWRUNNER™: Depends on Crestron License and Hardware
122 +|BACNET Points Supported|Depends on Crestron License and Hardware|ShowRunnerCLC™: Depends on Crestron License and Hardware
123 123  Floor Hub: 1000|1000|N/A
124 124  |Crestron Fusion|Y|(((
125 -SHOWRUNNER™: Y
125 +ShowRunnerCLC™: Y
126 126  Floor Hub: N
127 127  )))|N|N/A
128 -|Export to Zūm Floor Hub|Y, Licensed|SHOWRUNNER™: Y, Licensed|N/A|N/A
129 -|GLPAC|Y|SHOWRUNNER™: Y
130 -Floor Hub: Via SHOWRUNNER™|N|N/A
128 +|Export to Zūm Floor Hub|Y, Licensed|ShowRunnerCLC™: Y, Licensed|N/A|N/A
129 +|GLPAC|Y|ShowRunnerCLC™: Y
130 +Floor Hub: Via ShowRunnerCLC™|N|N/A
131 131  |System to System Link|Y|(((
132 -SHOWRUNNER™: Y
132 +ShowRunnerCLC™: Y
133 133  Floor Hub: N
134 134  )))|N|N/A
135 -|Minimum ZUM-NET Firmware|ZUM-WIRED 1.00.08 puf|N/A|See Crestron|See Crestron
136 -|Minimum SHOWRUNNER™ Version|2.208|N/A|N/A|N/A
135 +|Minimum ZUM-NET Firmware|(((
136 +CNET Mode: ZUM-WIRED 1.02.10 puf
137 +ZUM Mode: ZUM-WIRED  1.xx.xxx puf (Pending)
138 +)))|(((
139 +ShowRunnerCLC™: TBD
140 +Floor Hub: TBD
141 +)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01
142 +|Minimum SHOWRUNNER™ Version|(((
143 +CNET Mode: 3.016
144 +ZUM Mode: TBD
145 +)))|N/A|N/A|N/A
146 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE
147 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM
137 137  
138 138  {{id name="caveats"/}}
139 139  
... ... @@ -140,12 +140,15 @@
140 140  ==== Caveats ====
141 141  
142 142  * Consult Chief Integrations to verify sequence of operations if there are any concerns.
143 -* Additional caveats TBD
154 +* Additional caveats:
155 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.--  Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
156 +** --Raw Occupancy reporting does not work.  A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner.  ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.--  Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
157 +** Cresnet Discovery is not working on ZUMNET-JBOXs.  Crestron has acknowledged a fix has been sent to QE.  Discovery must be fixed before ShowRunner can auto-discover hardware.
144 144  
145 145  ==== FAQ: ====
146 146  
147 147  * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control?
148 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.//
162 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.  Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails.  [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//
149 149  * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration?
150 150  //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.//
151 151  
... ... @@ -153,10 +153,10 @@
153 153  
154 154  ==== Topologies ====
155 155  
156 -**SHOWRUNNER™ Total Control (Control Subnet or Flat)**
170 +**ShowRunnerCLC™ Total Control (Control Subnet or Flat)**
157 157  [[image:ZumWired_SR-CS\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology Control Subnet"]][[image:ZumWired_SR-Flat\@2x.png||alt="Flat Topology"]]
158 158  
159 -**SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)**
173 +**ShowRunnerCLC™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)**
160 160  [[image:ZumWired_SRtoFH\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]]
161 161  