Changes for page Crestron Zūm Wired
Last modified by Scott Kohlmann on 2023/04/20 22:22
From version 12.1
edited by Mark Kohlmann
on 2021/05/06 15:19
on 2021/05/06 15:19
Change comment:
There is no comment for this version
To version 13.1
edited by Mark Kohlmann
on 2021/10/05 22:11
on 2021/10/05 22:11
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,7 +9,7 @@ 9 9 10 10 ==== Feature Matrix ==== 11 11 12 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App* 12 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App* 13 13 |(% colspan="5" %)**Hardware Requirements** 14 14 |Requires ZUMNET JBox|Y|Y|Y|N 15 15 |Requires 3 or 4-Series Control System|Y|Y|N|N/A ... ... @@ -19,7 +19,7 @@ 19 19 |Web Browser|((( 20 20 Crestron SmartGraphics XPanel 21 21 HTML5 UI 22 -)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel 22 +)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel/HTML5 UI 23 23 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 24 |iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 25 |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N ... ... @@ -44,7 +44,7 @@ 44 44 Floor Hub: Category/Room|Category/Room|((( 45 45 N/A 46 46 ))) 47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices|SHOWRUNNER™: Automatic discovery 47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|SHOWRUNNER™: Automatic discovery (Pending) 48 48 Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A 49 49 |Network Topology|((( 50 50 * Flat ... ... @@ -132,8 +132,16 @@ 132 132 SHOWRUNNER™: Y 133 133 Floor Hub: N 134 134 )))|N|N/A 135 -|Minimum ZUM-NET Firmware|ZUM-WIRED 1.00.08 puf|N/A|See Crestron|See Crestron 136 -|Minimum SHOWRUNNER™ Version|2.208|N/A|N/A|N/A 135 +|Minimum ZUM-NET Firmware|((( 136 +CNET Mode: ZUM-WIRED 1.00.09 puf 137 +ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 138 +)))|N/A|See Crestron|See Crestron 139 +|Minimum SHOWRUNNER™ Version|((( 140 +CNET Mode: 3.003 141 +ZUM Mode: TBD 142 +)))|N/A|N/A|N/A 143 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE 144 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM 137 137 138 138 {{id name="caveats"/}} 139 139 ... ... @@ -140,12 +140,15 @@ 140 140 ==== Caveats ==== 141 141 142 142 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 143 -* Additional caveats TBD 151 +* Additional caveats: 152 +** Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 153 +** Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron. 154 +** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. 144 144 145 145 ==== FAQ: ==== 146 146 147 147 * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 148 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required.// 159 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails.// 149 149 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 150 150 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 151 151