Summary
-
Page properties (4 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome1 +Design Guide.Hardware Design Guide.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.scott\.kohlmann@chiefintegrations\.com - Hidden
-
... ... @@ -1,1 +1,1 @@ 1 - false1 +true - Content
-
... ... @@ -1,15 +1,15 @@ 1 - HOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design.1 +Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management. ShowRunnerCLC™ provides a number of integrations options that allow the designer to optimize the solution design. 2 2 3 3 ~*~*~* Specifications are preliminary, the Zūm wired ZUM-FLOOR-HUB has not been released ~*~** 4 4 5 5 ==== Integration Options ==== 6 6 7 -* **S HOWRUNNER™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design.8 -* **S HOWRUNNER™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. SHOWRUNNER™ can export its own areas to the Floor Hub.7 +* **ShowRunnerCLC™ Total Control** - The most comprehensive option. Allows seamless integration of Zūm and non-Zūm Crestron lighting control products. Extensive feature set allows centralized control and management of Zūm rooms. Advanced scheduler provides more flexibility to the facility operator. This solution replaces the ZUM-FLOOR-HUB in the system design. 8 +* **ShowRunnerCLC™ + ZUM-FLOOR-HUB** - Provides limited scene recall and room status for Zūm rooms paired with the Floor Hub. ShowRunnerCLC™ can export its own areas to the Floor Hub. 9 9 10 10 ==== Feature Matrix ==== 11 11 12 -|=Feature|=S HOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*12 +|=Feature|=ShowRunnerCLC™ Total Control|=ShowRunnerCLC™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App* 13 13 |(% colspan="5" %)**Hardware Requirements** 14 14 |Requires ZUMNET JBox|Y|Y|Y|N 15 15 |Requires 3 or 4-Series Control System|Y|Y|N|N/A ... ... @@ -19,9 +19,9 @@ 19 19 |Web Browser|((( 20 20 Crestron SmartGraphics XPanel 21 21 HTML5 UI 22 -)))|S HOWRUNNER™ - Crestron SmartGraphics XPanel22 +)))|ShowRunnerCLC™ - Crestron SmartGraphics XPanel/HTML5 UI 23 23 ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N 24 -|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 24 +|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y* 25 25 |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N 26 26 |(% colspan="5" %)**Features** 27 27 |Scene Recall|Y|Y|Y|Y ... ... @@ -28,7 +28,7 @@ 28 28 |Override Fade Time for Scene Recall|Y|TBD|TBD|TBD 29 29 |Scene Save|Y|TBD|TBD|Y 30 30 |Load Control|Y|TBD|TBD|Y 31 -|Demand Response|Y|Y, separate triggers for S HOWRUNNER™ and ZUM-FLOOR-HUB required|Y|N31 +|Demand Response|Y|Y, separate triggers for ShowRunnerCLC™ and ZUM-FLOOR-HUB required|Y|N 32 32 |Enable/Disable Occupancy|Y|Y, from Floor Hub|Y|Y 33 33 |Override Occupancy Logic|Y|TBD|TBD|N 34 34 |Override|Y|Scene Recall only via ShowRunner|TBD|N/A ... ... @@ -35,22 +35,22 @@ 35 35 |Plug Load On/Off|Y|Y|Y|By Hardware 36 36 |Integration with Non-Zūm Crestron Hardware|Y|N|N|N 37 37 |Custom Zūm Keypad Programming|Y|TBD|TBD|Y, within the limits of the hardware 38 -|New Feature Release Cycle|Aggressive|S HOWRUNNER™: Aggressive38 +|New Feature Release Cycle|Aggressive|ShowRunnerCLC™: Aggressive 39 39 Floor Hub: 6-12 months|6-12 months|6-12 months 40 40 |Room Organization|((( 41 41 Organize According to Defined Nodes, multiple levels 42 42 Categorization to Filter by Tag 43 -)))|S HOWRUNNER™: See SHOWRUNNER™ Total Control43 +)))|ShowRunnerCLC™: See ShowRunnerCLC™ Total Control 44 44 Floor Hub: Category/Room|Category/Room|((( 45 45 N/A 46 46 ))) 47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices|S HOWRUNNER™: Automatic discovery48 -Floor Hub: Map Mirrored Rooms to S HOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|ShowRunnerCLC™: Automatic discovery (Pending) 48 +Floor Hub: Map Mirrored Rooms to ShowRunnerCLC™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A 49 49 |Network Topology|((( 50 50 * Flat 51 51 * Single Handoff to LAN w/ Control Subnet 52 52 (Requires CP4N/AV4/PRO4) 53 -)))|Single Handoff to LAN w/ Control Subnet. ShowRunner can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A 53 +)))|Single Handoff to LAN w/ Control Subnet. ShowRunnerCLC™ can be on LAN or Control Subnet|Single Handoff to LAN w/ Control Subnet|N/A 54 54 |Network Addressing|((( 55 55 * Manual 56 56 * Customer (DHCP or Manual) ... ... @@ -57,30 +57,30 @@ 57 57 * DHCP: Control Subnet (Requires CP4N/AV4/PRO4) 58 58 )))|Control Subnet|Control Subnet|N/A 59 59 |Firmware Updates|PUF Tool 60 -Automatic Support on Roadmap|S HOWRUNNER™: PUF Tool60 +Automatic Support on Roadmap|ShowRunnerCLC™: PUF Tool 61 61 Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A 62 -|Floorplans|Y|S HOWRUNNER™: Y62 +|Floorplans|Y|ShowRunnerCLC™: Y 63 63 Floor Hub: N|N|N/A 64 64 |(% colspan="5" %)**Calendar/Scheduling** 65 65 |Logic Type|Event Driven 66 -Profile Support (Under Development)|S HOWRUNNER™: Event Driven66 +Profile Support (Under Development)|ShowRunnerCLC™: Event Driven 67 67 Floor Hub: Pattern assigned to Category|Pattern assigned to Category|N/A 68 68 |Astronomical Clock|Y|Y, Per Category|Y, Per Category|N/A 69 -|Holidays|Pattern|S HOWRUNNER™: Pattern69 +|Holidays|Pattern|ShowRunnerCLC™: Pattern 70 70 Floor Hub: Hard Coded|Hard Coded|N/A 71 -|Custom Patterns|Y, Advanced Scheduler License|S HOWRUNNER™: Y, Advanced Scheduler License71 +|Custom Patterns|Y, Advanced Scheduler License|ShowRunnerCLC™: Y, Advanced Scheduler License 72 72 Floor Hub: N|N|N/A 73 73 |(% colspan="5" %)**Integrations** 74 -|A/V Integration: API|Y|S HOWRUNNER™: Y74 +|A/V Integration: API|Y|ShowRunnerCLC™: Y 75 75 Floor Hub: Limited|Limited|N/A 76 -|A/V Integration: Crestron EISC|Y|S HOWRUNNER™: Y76 +|A/V Integration: Crestron EISC|Y|ShowRunnerCLC™: Y 77 77 Floor Hub: N|N|N/A 78 78 |A/V Integration: RS-232|Y|((( 79 -S HOWRUNNER™: Y80 -Floor Hub: AVBRIDGE per Area81 -)))| AVBRIDGE per Area|N/A79 +ShowRunnerCLC™: Y 80 +Floor Hub: TBD 81 +)))|TBD|N/A 82 82 |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|((( 83 -S HOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed83 +ShowRunnerCLC™: ShowRunnerCLC™ and Crestron Licenses Needed 84 84 Floor Hub: Y 85 85 )))|Y|N/A 86 86 |BACNET Features|((( ... ... @@ -98,7 +98,7 @@ 98 98 99 99 ~* More Features added upon request 100 100 )))|((( 101 -S HOWRUNNER™: See list for SHOWRUNNER™ Total Control101 +ShowRunnerCLC™: See list for ShowRunnerCLC™ Total Control 102 102 Floor Hub: See list for ZUM-FLOOR-HUB 103 103 )))|((( 104 104 Per Room Status: ... ... @@ -116,24 +116,35 @@ 116 116 )))|N/A 117 117 |BACNET Settings Scope 118 118 (What Points are Exposed)|Per Area|((( 119 -S HOWRUNNER™: Per Area119 +ShowRunnerCLC™: Per Area 120 120 Floor Hub: Global 121 121 )))|Global|N/A 122 -|BACNET Points Supported|Depends on Crestron License and Hardware|S HOWRUNNER™: Depends on Crestron License and Hardware122 +|BACNET Points Supported|Depends on Crestron License and Hardware|ShowRunnerCLC™: Depends on Crestron License and Hardware 123 123 Floor Hub: 1000|1000|N/A 124 124 |Crestron Fusion|Y|((( 125 -S HOWRUNNER™: Y125 +ShowRunnerCLC™: Y 126 126 Floor Hub: N 127 127 )))|N|N/A 128 -|Export to Zūm Floor Hub|Y, Licensed|S HOWRUNNER™: Y, Licensed|N/A|N/A129 -|GLPAC|Y|S HOWRUNNER™: Y130 -Floor Hub: Via S HOWRUNNER™|N|N/A128 +|Export to Zūm Floor Hub|Y, Licensed|ShowRunnerCLC™: Y, Licensed|N/A|N/A 129 +|GLPAC|Y|ShowRunnerCLC™: Y 130 +Floor Hub: Via ShowRunnerCLC™|N|N/A 131 131 |System to System Link|Y|((( 132 -S HOWRUNNER™: Y132 +ShowRunnerCLC™: Y 133 133 Floor Hub: N 134 134 )))|N|N/A 135 -|Minimum ZUM-NET Firmware|ZUM-WIRED 1.00.08 puf|N/A|See Crestron|See Crestron 136 -|Minimum SHOWRUNNER™ Version|2.208|N/A|N/A|N/A 135 +|Minimum ZUM-NET Firmware|((( 136 +CNET Mode: ZUM-WIRED 1.02.10 puf 137 +ZUM Mode: ZUM-WIRED 1.xx.xxx puf (Pending) 138 +)))|((( 139 +ShowRunnerCLC™: TBD 140 +Floor Hub: TBD 141 +)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01 142 +|Minimum SHOWRUNNER™ Version|((( 143 +CNET Mode: 3.016 144 +ZUM Mode: TBD 145 +)))|N/A|N/A|N/A 146 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE 147 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM 137 137 138 138 {{id name="caveats"/}} 139 139 ... ... @@ -140,12 +140,15 @@ 140 140 ==== Caveats ==== 141 141 142 142 * Consult Chief Integrations to verify sequence of operations if there are any concerns. 143 -* Additional caveats TBD 154 +* Additional caveats: 155 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 156 +** --Raw Occupancy reporting does not work. A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner. ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored. This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.-- Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron. 157 +** Cresnet Discovery is not working on ZUMNET-JBOXs. Crestron has acknowledged a fix has been sent to QE. Discovery must be fixed before ShowRunner can auto-discover hardware. 144 144 145 145 ==== FAQ: ==== 146 146 147 147 * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control? 148 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required.// 162 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB. A DIN-AP4 is not required. Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails. [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]// 149 149 * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration? 150 150 //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.// 151 151 ... ... @@ -153,10 +153,10 @@ 153 153 154 154 ==== Topologies ==== 155 155 156 -**S HOWRUNNER™ Total Control (Control Subnet or Flat)**170 +**ShowRunnerCLC™ Total Control (Control Subnet or Flat)** 157 157 [[image:ZumWired_SR-CS\@2x.png||alt="Zum SHOWRUNNER™ Total Control Topology Control Subnet"]][[image:ZumWired_SR-Flat\@2x.png||alt="Flat Topology"]] 158 158 159 -**S HOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)**173 +**ShowRunnerCLC™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)** 160 160 [[image:ZumWired_SRtoFH\@2x.png||alt="Zum Floor Hub + SHOWRUNNER™ Topology"]] 161 161 162 162 **ZUM-FLOOR-HUB Only**