Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ User Guide & Wiki.Design Guide.Hardware Design Guide.WebHome
1 +Design Guide.Hardware Design Guide.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.mark\.kohlmann@chiefintegrations\.com
1 +XWiki.alexander\.mott@chiefintegrations\.com
Hidden
... ... @@ -1,1 +1,1 @@
1 -false
1 +true
Content
... ... @@ -1,4 +1,4 @@
1 - Crestron Zūm Wired is a locally integrated lighting control system with various global control options.  Zūm rooms are self-contained control units with primary logic occurring at the room level.  Central control systems offer scheduling and management.  SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design.
1 +Crestron Zūm Wired is a locally integrated lighting control system with various global control options. Zūm rooms are self-contained control units with primary logic occurring at the room level. Central control systems offer scheduling and management.  SHOWRUNNER™ provides a number of integrations options that allow the designer to optimize the solution design.
2 2  
3 3  ~*~*~* Specifications are preliminary, the Zūm wired ZUM-FLOOR-HUB has not been released ~*~**
4 4  
... ... @@ -9,7 +9,7 @@
9 9  
10 10  ==== Feature Matrix ====
11 11  
12 -|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB (Mirror Driver)|=ZUM-FLOOR-HUB Only|=Zūm iOS/Android Setup App*
12 +|=Feature|=SHOWRUNNER™ Total Control|=SHOWRUNNER™ (External Room Export) + ZUM-FLOOR-HUB4 (Mirror Driver)|=ZUM-FLOOR-HUB4 Only|=Zūm iOS/Android Setup App*
13 13  |(% colspan="5" %)**Hardware Requirements**
14 14  |Requires ZUMNET JBox|Y|Y|Y|N
15 15  |Requires 3 or 4-Series Control System|Y|Y|N|N/A
... ... @@ -19,9 +19,9 @@
19 19  |Web Browser|(((
20 20  Crestron SmartGraphics XPanel
21 21  HTML5 UI
22 -)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel
22 +)))|SHOWRUNNER™ - Crestron SmartGraphics XPanel/HTML5 UI
23 23  ZUM-FLOOR-HUB - HTML5 UI|HTML5 UI|N
24 -|iOS/Android|Y, Crestron App (Paid Upgrade)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
24 +|iOS/Android|Y, Crestron App (Paid Upgrade) or HTML5 UI (Device Web Browser)|Y, Crestron App (Paid Upgrade), Limited Features for Zūm Rooms|N|Y*
25 25  |Touchscreens (Crestron TSW series)|Y|Y, Limited Features for Zūm Rooms|N|N
26 26  |(% colspan="5" %)**Features**
27 27  |Scene Recall|Y|Y|Y|Y
... ... @@ -44,7 +44,7 @@
44 44  Floor Hub: Category/Room|Category/Room|(((
45 45  N/A
46 46  )))
47 -|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices|SHOWRUNNER™: Automatic discovery
47 +|Room Discovery|Automatic Discovery of ZUMNET and ZUMLINK devices (Pending)|SHOWRUNNER™: Automatic discovery (Pending)
48 48  Floor Hub: Map Mirrored Rooms to SHOWRUNNER™ and Discovery External Rooms|Automatic Discovery of ZUMNET and ZUMLINK devices|N/A
49 49  |Network Topology|(((
50 50  * Flat
... ... @@ -59,6 +59,8 @@
59 59  |Firmware Updates|PUF Tool
60 60  Automatic Support on Roadmap|SHOWRUNNER™: PUF Tool
61 61  Floor Hub: Automatic, Internet Connection Required|Automatic, Internet Connection Required|N/A
62 +|Floorplans|Y|SHOWRUNNER™: Y
63 +Floor Hub: N|N|N/A
62 62  |(% colspan="5" %)**Calendar/Scheduling**
63 63  |Logic Type|Event Driven
64 64  Profile Support (Under Development)|SHOWRUNNER™: Event Driven
... ... @@ -75,8 +75,8 @@
75 75  Floor Hub: N|N|N/A
76 76  |A/V Integration: RS-232|Y|(((
77 77  SHOWRUNNER™: Y
78 -Floor Hub: AVBRIDGE per Area
79 -)))|AVBRIDGE per Area|N/A
80 +Floor Hub: TBD
81 +)))|TBD|N/A
80 80  |BACNET|Y, SHOWRUNNER™ and Crestron Licenses Needed|(((
81 81  SHOWRUNNER™: SHOWRUNNER™ and Crestron Licenses Needed
82 82  Floor Hub: Y
... ... @@ -130,8 +130,19 @@
130 130  SHOWRUNNER™: Y
131 131  Floor Hub: N
132 132  )))|N|N/A
133 -|Minimum ZUM-NET Firmware|ZUM-WIRED 1.00.08 puf|N/A|See Crestron|See Crestron
134 -|Minimum SHOWRUNNER™ Version|2.208|N/A|N/A|N/A
135 +|Minimum ZUM-NET Firmware|(((
136 +CNET Mode: ZUM-WIRED 1.02.10 puf
137 +ZUM Mode: ZUM-WIRED  1.xx.xxx puf (Pending)
138 +)))|(((
139 +SHOWRUNNER™: TBD
140 +Floor Hub: TBD
141 +)))|See Crestron, expected to be v1.01|See Crestron, expected to be v1.01
142 +|Minimum SHOWRUNNER™ Version|(((
143 +CNET Mode: 3.016
144 +ZUM Mode: TBD
145 +)))|N/A|N/A|N/A
146 +|ZWMS (Zum Wired Master/Slave Mode)|MASTER|Same as Floor Hub|MASTER|MASTER or SLAVE
147 +|ZWMODE|CNET or ZUM (ZUM Support Pending official release from Crestron)|Same as Floor Hub|ZUM|ZUM
135 135  
136 136  {{id name="caveats"/}}
137 137  
... ... @@ -138,19 +138,20 @@
138 138  ==== Caveats ====
139 139  
140 140  * Consult Chief Integrations to verify sequence of operations if there are any concerns.
141 -* Additional caveats TBD
154 +* Additional caveats:
155 +** --Occupancy status is not reported to ShowRunner when ZUMNET/ZUMLINK JBOXs come online.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.--  Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
156 +** --Raw Occupancy reporting does not work.  A delay of 5 seconds to 5 minutes between sensor vacancy and reported vacancy to ShowRunner.  ShowRunner attempts to set 30 seconds (v3.003 to v3.009) or 5 seconds (v3.010 and later) but it is not always honored.  This has been acknowledged as a bug by Crestron in firmware v1.001.054 and v1.00.009 and is pending a fix from Crestron.--  Fixed in 1.02.010 firmware and Device Database 200.150.002, ShowRunner 3.016 has been updated with these fixes from Crestron.
157 +** Cresnet Discovery is not working on ZUMNET-JBOXs.  Crestron has acknowledged a fix has been sent to QE.  Discovery must be fixed before ShowRunner can auto-discover hardware.
142 142  
143 143  ==== FAQ: ====
144 144  
145 145  * I want to have a single connection to the building and have all of my Crestron devices on the Control Subnet (same topology as a ZUM-FLOOR-HUB) and use ShowRunner™ Total Control?
146 -//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.//
162 +//Use a CP4N in lieu of the ZUM-FLOOR-HUB.  A DIN-AP4 is not required.  Crestron can supply a DIN-EN-6X18 with CEN-SW-POE-16 and CP4N racked in a 2RU mount plus 3 DIN rails.  [[See Design Details.>>doc:Design Guide.Hardware Design Guide.Crestron Zūm Wired.Design to co-locate a CP4N and CEN-SWPOE-16 in the Same DIN-EN Cabinet.WebHome]]//
147 147  * Do I need a Crestron BACnet license when using ShowRunner for BACnet integration?
148 148  //If over 50 BACnet points are needed then a license (SW-3SERIES-BACNET-50+) will be needed for each Crestron processor that will provide BACnet points to the BMS.//
149 149  
150 -(% class="wikigeneratedid" %)
151 151  ==== ====
152 152  
153 -(% class="wikigeneratedid" %)
154 154  ==== Topologies ====
155 155  
156 156  **SHOWRUNNER™ Total Control (Control Subnet or Flat)**