Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.mark\.kohlmann@chiefintegrations\.com
1 +XWiki.scott\.kohlmann@chiefintegrations\.com
Content
... ... @@ -1,5 +1,22 @@
1 -SHOWRUNNER™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.
1 +ShowRunnerCLCis a commercial lighting control and lighting management system.  ShowRunnerCLC™ contains a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.  Hardware support is extensive and growing all the time.  This document is not a complete feature list and Chief Integrations reserves the right to make modifications at any time.
2 2  
3 +{{box cssClass="floatinginfobox"}}
4 +(% class="wikigeneratedid wikigeneratedheader" id="HTableofContents" %)
5 +**CONTENTS**
6 +
7 +{{toc start="4"/}}
8 +{{/box}}
9 +
10 +==== Key Capabilities ====
11 +
12 +* Configuration driven with runtime adaptability enables rapid commissioning of commercial lighting systems
13 +* Extensive feature set allows Crestron systems to comply with the majority of DIV 26s and customer requirements
14 +* Large native hardware support with the ability to extend support to new hardware quickly and easily
15 +* Touchpanel and web based UIs cover users' needs
16 +* Runs entirely on a Crestron processor or VC-4 eliminating the need to manage expensive servers
17 +* Floorplans with pinch, zoom, and insight!
18 +* Powerful scheduling capabilities enable set and forget scheduling of lighting and easy management to handle changes
19 +
3 3  ==== Area Features ====
4 4  
5 5  * Lighting Loads
... ... @@ -6,8 +6,9 @@
6 6  * Scene recall
7 7  * Master raise/lower
8 8  * User configurable scene name, fade time, and load include by scene
26 +* Individual scenes may be locked to prevent changing their settings
9 9  * Individual load control within an area
10 -* Select area from touchpanel, areas can be restricted by panel
28 +* Area selection from touchpanel, areas can be restricted by panel
11 11  * RGB controls for applicable fixtures, saved per scene
12 12  * Configurable Load Grouping for load consolidation including linked/group area loads
13 13  * Dynamic White/Circadian Rhythm CCT Control
... ... @@ -14,7 +14,6 @@
14 14  ** CCT Control per area for applicable fixtures
15 15  ** Global schedule for CCT, astronomical and/or fixed schedules
16 16  ** Manual CCT override per area
17 -** Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking
18 18  * Demand Response with ability to exclude area from Demand Response event
19 19  * Configurable load grouping allows aggregation of loads to a single slider per group, can include linked areas
20 20  * HVAC Control
... ... @@ -31,6 +31,7 @@
31 31  * After Hours support for automatic shutoff after configurable timeout w/ alerting
32 32  * Parent Area feature allows one area to trickle down scene recall and raise/lower (if enabled)
33 33  * Last Scene Recall timestamp and triggering action recorded
51 +* Organized in a node tree with multiple depths
34 34  
35 35  ==== Load Features ====
36 36  
... ... @@ -67,7 +67,7 @@
67 67  * Demand Response Level
68 68  * Enable/Disable/Override states
69 69  * Option to ignore long fade times if the loads is off
70 -* Option recall last level
88 +* Option to recall last on level
71 71  * Individual daylight harvesting settings, enabled/disabled by scene
72 72  ** Open/closed loop
73 73  ** Min/Max levels
... ... @@ -87,13 +87,12 @@
87 87  * DALI (DIN-DALI-2/ZUMNET-JBOX-DALI Legacy mode)
88 88  ** Addressing/Grouping/Driver Replacement for DALI.  DALI groups are referenced by their controlled load simplifying addressing and replacement procedures.
89 89  
90 -(% class="wikigeneratedid" %)
91 91  ==== Scheduling Features ====
92 92  
93 -* Algorithm based scheduling engine ensures predictable operation year after year with no need to specifically specify each day
110 +* Algorithm based scheduling engine ensures predictable operation year after year with no need to define a system wide schedule per-day
94 94  * Area and/or Tag based schedules
95 95  * Individual global events or grouped events
96 -* showrunner™ HUB UI Features
113 +* ShowRunnerCLC™ HUB UI Features
97 97  ** Day/Week/Month/Time Grid views display all events calculated by the scheduler engine
98 98  ** Tree based event/event groups
99 99  ** View Built-In Calendars and Groups
... ... @@ -133,18 +133,43 @@
133 133  **** Optional: Calculate Observed Weekday Date Before, After, or BeforeOrAfter
134 134  *** Enable/Disable
135 135  ** Pre-loaded with US Federal and common non-Federal US Holidays
153 +** Support for additional algorithms available upon request
136 136  
137 -=== Supported Hardware Features ===
155 +==== Circadian Rhythm/Dynamic White ====
138 138  
157 +* Global system CCT Level
158 +* Override CCT per area by scene or manually
159 +* Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking
160 +* Time period based
161 +** Time References for start and end of period
162 +*** AM/PM
163 +*** Relative to
164 +**** Sunrise
165 +**** Sunset
166 +**** Solar Noon
167 +** Each time period can have the following setting for CCT
168 +*** Static
169 +*** Linear change over time
170 +*** Sensor with configured CCT when sensor is out of range
171 +* Supported with 0-10V, DMX, and DALI. Additional support via APIs
172 +
173 +==== Supported Hardware Features ====
174 +
175 +Virtually the entire Crestron lighting product line is supported along with several 3rd party products
176 +
139 139  * Common Settings to all devices
140 140  ** Contractor Label
141 141  ** Name
142 142  ** GlobalId
143 143  ** UniqueId (GUID)
182 +* HVAC
183 +** Temperature control by area
184 +** Support for some Crestron Thermostats, more can be added as needed
185 +** Support for some 3rd party systems, more can be added as needed
144 144  * Keypads
145 -** Support for common fixed configurations, user assignable at runtime
187 +** Support for common fixed configurations, user assignable at runtime. Includes all standard Crestron SpecsBuilder types.
146 146  ** Custom keypads with configurable actions per button at runtime
147 -*** Graphic based programming using showrunnerHUB UI
189 +*** Graphic based programming using ShowRunnerHUB™ UI
148 148  *** Master raise/lower button support allows assignment of currently selected load/shade/area/etc
149 149  *** Custom button layouts w/ labels to assist with generating engravings
150 150  ** Flexible Templating Engine
... ... @@ -158,9 +158,9 @@
158 158  ** Flip raise/lower on common keypad types
159 159  ** Configurable hold time support, done in software if not supported by hardware
160 160  ** Configurable double tap time support if supported by hardware
161 -** Simulate keypads from showrunner™ HUB UI or console
203 +** Simulate keypads from ShowRunnerCLC™ HUB UI or console
162 162  ** Direct load mapping for some common keypads
163 -* Keyswitch and Contact Closure Inputs
205 +* Keyswitch/Contact Closure Inputs
164 164  ** Supports all versiport and digital inputs
165 165  ** Maintained and Momentary supported
166 166  ** Feedback output supported
... ... @@ -169,28 +169,61 @@
169 169  *** Scene Recall for Active and Inactive States
170 170  *** Demand Response
171 171  *** Actions for Active and Inactive States
214 +** Commonly used for FACP, override, demand response, and panic inputs
172 172  * Occupancy Sensors:
173 173  ** Occupancy configuration for CN and ZUMLINK occupancy sensors
174 174  ** ​3rd Party and Non-System occupancy sensor support
175 175  ** Occupancy/Vacancy/Disabled/Use Hardware Logic modes, user configurable
176 176  ** Configure scenes recalled by area for occupancy and vacancy states
177 -** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance
220 +** Individual max unoccupied level by load for IECC 2018 C405.2.1.3 compliance (open office 600sqft)
178 178  ** User configurable assignment of sensor to area(s) and load(s)
179 179  ** Occupancy sensors may feed data to multiple areas and loads
180 180  ** Last occupied and vacant times recorded
224 +* Output Signal
225 +** Logic object capable of triggering additional logic
226 +** Can trigger physical outputs via versiports/IOs
227 +** Supports conditional logic
228 +** Independent actions for active/inactive states
229 +** Configurable delays for active/inactive execution
181 181  * Partition sensors
182 182  ** Support for divisible areas
183 183  ** GLS-PART-CN with adjustable sensitivity
184 184  ** 3rd party sensor support via hardware inputs
185 -** User configurable Auto, Combined, and Divided
234 +** User configurable Auto (use sensor) with manual override for Combined and Divided
186 186  ** Filtering to ignore noisy partition sensors
187 -** Change count and last change recorded
236 +** Change count and last change recorded help troubleshoot
237 +** Hardware not required, may be setup as a virtual sensor
238 +* Photocell
239 +** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior)
240 +** Configurable coefficient
241 +** Configurable thresholds
242 +** Assignable to individual loads for daylight harvesting
243 +* Serial Interface
244 +** RS-232/422/484 depending on hardware
245 +** Configurable Baud Rate and Com settings
246 +** Simple ASCII API for controlling/monitoring
247 +** Areas/Loads/Occupancy/Partition/Shades supported
248 +* Shades
249 +** Support for Crestron shades/drapes
250 +** Support for many 3rd party shade and drape systems
251 +* Zum Wired
252 +** Edge logic operation in Zum App mode
253 +*** Override occupancy logic and use ShowRunnerCLC™ logic
254 +** Central logic in CNET mode
255 +** Cresnet devices attached to ZUMNET-JBOXs in either Edge or Central modes
256 +* Zum Wireless
257 +** Override keypad buttons (except buttons 5-6)
258 +** Edge logic operation
259 +** Override occupancy behavior with ShowRunnerCLC™ logic
260 +** Direct load control
261 +** Scene save
262 +* Support for configuring hardware symbol properties on Crestron hardware
188 188  
189 189  ==== Energy Efficiency ====
190 190  
191 191  * Demand Response/Load Shedding
192 192  ** Automatic via sensor input
193 -** Manually via keypad
268 +** Manually via user input
194 194  * Calculated or Measured Power (Watts)
195 195  * Energy Efficiency visualization on floorplan
196 196  
... ... @@ -197,7 +197,7 @@
197 197  ==== Security ====
198 198  
199 199  * Touchscreens: Global User and Technician Passcodes, user configurable.
200 -* showrunner™ HUB
275 +* ShowRunnerCLC™ HUB
201 201  ** Role Based permissions by Group
202 202  ** Granular Create, Edit, View, Delete, and Execute permissions by Role
203 203  ** Users and API Users assignable to groups
... ... @@ -205,18 +205,204 @@
205 205  ** HTTPS enforced
206 206  ** Auto session timeout
207 207  ** Login via username/password or PIN code
208 -** Support for Processor or internal user database
283 +** Support for Processor and internal user database with configurable priority or specify one exclusively
209 209  ** Best practices for password handling
210 -* API Users using AWSv4 scheme for authentication per request for maximum security
285 +* API using AWSv4 scheme for authentication per request for maximum security
286 +* Encrypted storage of all credentials and keys
211 211  
212 -==== System Settings ====
288 +==== General Features ====
213 213  
214 214  * User configurable time zone, location, and current time
215 215  * Addressing and Verification of Cresnet devices by serial number
216 216  * Cresnet Device Serial Number capture
217 -* Configurable Global Actions with touchpanel trigger
218 -* Remote hardware support from neighbor ShowRunner System:
219 -** ​Allows a master ShowRunner system to integrate slave processors
293 +* Extensive console command interface (CLI)
294 +* Simulate sensor and keypad inputs to test without hardware
295 +* DHCP server on single LAN processors allows setup of isolated networks without additional DHCP server. 
296 +Note: DHCP server is not designed to be used in production and will automatically be disabled on a reboot, use for setup only.
297 +
298 +==== Diagnostics ====
299 +
300 +* Provides diagnostic data when supported by hardware
301 +* Diagnostics available from load controllers all the way up to Cresnet bridges
302 +* Status indications quickly assist with identifying severity of the problem: Normal, Warning, Critical, Status Only
303 +
304 +==== Discovery ====
305 +
306 +* Discover and automatically define Zum Wired hardware
307 +* Discover and automatically define Zum Wireless hardware
308 +* Discover Cresnet devices connected to the system, automatic addressing for configured hardware by serial number
309 +* Discover and claim select Crestron Ethernet devices connected to the local network, automatic IP Table setup when claiming
310 +
311 +==== Event Log ====
312 +
313 +* Central logging mechanism
314 +* Messages time stamped
315 +* CSV format
316 +* Multiple logging levels: Critical, Error, Warning, Information, Debug, Trace
317 +* Filter by logging level
318 +* Filter by source object
319 +* Filter by GlobalId
320 +* Trace option allows tracking the triggering event through execution
321 +* Thread option allows tracking of the thread executing
322 +* Logging to console
323 +* Logging to file
324 +* Logging to remote syslog (via processor)
325 +* Heartbeat option with configurable interval
326 +* Debugging writes to the event log
327 +* Global Enable flag
328 +
329 +==== Extensibility ====
330 +
331 +* Actions
332 +** Logic objects exist on ShowRunnerCLC™ objects
333 +** Functionality can be triggered via APIs
334 +** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within ShowRunnerCLC™
335 +* Extensions
336 +** Extension model allows customization and additional functionality to be added to the ShowRunnerCLC™ ecosystem
337 +** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]]
338 +* Global Actions
339 +** Allow manual or input triggered operations against the system
340 +** Can be custom programmed at runtime
341 +
342 +==== User Interfaces ====
343 +
344 +* ShowRunnerHUB™
345 +** Web based, touch and mouse friendly design
346 +** Runs directly on the processor or VC-4 instance
347 +** HTTPS required
348 +** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience
349 +** Node Tree
350 +*** Organize areas in logical locations based on physical topology
351 +*** Searchable, only shows matching areas
352 +** Floorplans
353 +*** Assigned to a node, multiple floor plans are supported
354 +*** Pinch zoom/touch pan
355 +*** User provided floorplan
356 +*** Draw directly on floorplan for areas and objects
357 +**** Areas
358 +**** Loads
359 +**** Partitions
360 +**** Occupancy Sensors
361 +**** Keypads
362 +**** Photocells
363 +*** Crestron product line icons area available to match the installed sensor
364 +*** Interactive control screens depending on clicked object
365 +*** Multiple different views help visualize data
366 +**** Area View - Shows areas with user selected colors
367 +**** Tags View - Shows areas based on their assigned tag
368 +**** Occupancy View - Shows areas based on their current occupancy status and how recently that status changed
369 +**** Intensity View - Shows areas shaded based on the current overall light intensity
370 +**** Energy View - Shows areas shaded based on the areas current energy efficiency from efficient to inefficient
371 +*** Automatic navigation to area when selected from the node tree
372 +*** Fullscreen view
373 +** Schedule
374 +*** See [[Scheduling Features>>doc:||anchor="Scheduling Features"]] for more info
375 +** Reports
376 +*** Interactive data
377 +**** Area Loads
378 +**** Area Scenes
379 +**** Areas
380 +**** Cresnet (Query)
381 +**** Device Status
382 +**** Events
383 +**** Keypads
384 +** Setup
385 +*** Device Diagnostic - Show Diagnostic data from supported devices
386 +*** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies
387 +*** File Management - Manage config, license, currently active config, and backup/restore operations
388 +*** Global Actions - Add/Delete/Configure
389 +*** Integrations - Manage integrations with other ShowRunnerCLC™ systems
390 +*** Keypad Configuration - Configure keypads
391 +*** Maps - Add/Manage floorplan images
392 +*** Network - DHCP Server (for processors without routers only)
393 +*** System Settings - Manage various system settings
394 +*** Tags - Manage tags and association of tags with areas
395 +*** User Management - Manage users/groups/API users
396 +* Crestron TS/TSWs and Crestron App (iPad/iPhone/Android)
397 +** Area Control Screen
398 +*** Select Area (Can be disabled or restricted)
399 +*** Divide/Combine status, if divisible
400 +*** Occupancy/vacancy status, if has an occupancy sensor
401 +*** Individual load controls
402 +*** Dynamic white color temperature control, if supported
403 +*** RGB color picker, if load supported
404 +*** Scenes, up to 20, save with press and hold
405 +*** Master Raise/Lower
406 +*** Global Actions, if defined, can be hidden
407 +*** HVAC controls, if supported
408 +*** Shade controls, if supported
409 +*** Passcode protected, if enabled
410 +** Setup Screen
411 +*** Passcode protected, if enabled
412 +*** Area Configuration
413 +**** Area List
414 +**** Area Name, editable
415 +**** Load Configuration - Configure load control type and labeling, test fixture operation
416 +**** Occupancy Setup - Configure area occupancy behavior and occupancy settings
417 +**** Daylight Harvesting - Configure daylight harvesting settings per load/scene
418 +**** Scene Setup - Configure and add/delete scenes
419 +**** Properties - Configure area behavior settings
420 +**** Add/Delete areas
421 +*** Area Layout - Configure partition sensors and area assignments to partition sensors
422 +*** Crestron Integration - Configure EISCs
423 +*** Device Addressing - Address and verify Cresnet devices
424 +*** Keypad Configuration - Configure keypad type, area assignment, and enable status
425 +*** Load Hardware - Configure loads and load controllers
426 +*** Location and System Clock - View/Set system clock, site lat/lon, and timezone
427 +*** Occupancy Assignment - Assign occupancy sensors to loads/areas
428 +*** Scheduler / Events - Add/Edit/Delete events, configure calendars, configure actions (for non-group events)
429 +*** Security Settings - Enable/Disable/Change PIN codes
430 +*** Zum Integration - Configure export to Zum Floor Hub
431 +*** Help Screen - Support contact information,  ShowRunnerCLC™ version list, and license status
432 +** Custom Logo option for splash screen
433 +** Optional floor plan area selection, zoom/pan are NOT supported, static image only
434 +** Optional partition control on floor plan screen
435 +
436 +=== Integrations ===
437 +
438 +* AV Integration protocol via serial port, simple ASCII protocol with feedback
439 +* BACnet Support for integration of Areas, Loads (Licensed Feature, both ShowRunnerCLC™ and Crestron)
440 +** Global
441 +*** Override
442 +*** Demand Response
443 +*** Device Offline Count
444 +*** Alarm
445 +*** System Normal/After Hours
446 +** Area Specific
447 +*** ShowRunnerCLC™ Mode
448 +**** Occupancy Status
449 +**** Occupancy Enable
450 +**** Scenes
451 +**** Loads
452 +**** Photocell Level
453 +**** Overall Intensity
454 +**** Power (watts)
455 +*** Zum Hub Emulation Mode
456 +**** Online
457 +**** On
458 +**** Scenes
459 +**** Occupied
460 +**** Occupancy Sensor Enable
461 +* Crestron Fusion EM (Licensed Feature)
462 +** Scenes, Recall and Save
463 +** Load Control
464 +** Occupancy Status
465 +** Photocell
466 +* e-DMX Receiver
467 +** SACN and/or Art-Net
468 +** Enable/Disable control for loads using e-DMX channel value
469 +** Map DMX to ShowRunnerCLC™ loads
470 +* EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client)
471 +** Configurable IP address and IP-ID, change at runtime
472 +** Configurable rooms to export, change at runtime
473 +** Changes generate new RSD file at runtime that may be provided to the AV programmer
474 +* HTTP REST API w/ Authorization
475 +* Lightweight API provides real-time control/feedback using CoAP
476 +* TCP Interface using simple ASCII commands, subscriptions supported
477 +* UDP Receiver using simple ASCII commands
478 +* Zum Floor Hub Support for integration, Export ShowRunnerCLC™ areas to the Floor Hub (Licensed Feature)
479 +* Remote hardware support from neighbor ShowRunnerCLC™ System:
480 +** ​Allows a central ShowRunner system to integrate edge processors
220 220  ** AV Serial Interface
221 221  ** Loads
222 222  ** Controllers
... ... @@ -225,24 +225,9 @@
225 225  ** Occupancy Sensor (including setup for Cresnet sensors)
226 226  ** Partition Sensors (including setup for Cresnet sensors)
227 227  ** Photocells
228 -* Web based reporting directly from the processor allows generation of as built documentation: Cresnet Discovery, Device Status, Event Schedule, Keypad Schedule, Load Schedule, and Panel Schedule
229 229  
230 -=== Integrations ===
490 +==== Reporting ====
231 231  
232 -* AV Integration protocol via serial port
233 -* BACNET Support for integration of Areas, Loads (Licensed Feature)
234 -* Crestron Fusion (Licensed Feature)
235 -* E-DMX Receiver
236 -** SACN or Art-Net
237 -** Enable/Disable control for loads
238 -** Map DMX to showrunner loads
239 -* EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client)
240 -* HTTP REST API w/ Authorization
241 -* Lightweight API provides real-time control/feedback of hardware using CoAP
242 -* Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature)
243 -
244 -=== Reporting ===
245 -
246 246  ShowRunner provides a website via the processor's internal webserver with the following reports.  All data is live at the time of the generation of the report.
247 247  
248 248  * Area Load Schedule - Load schedule by Area