Changes for page Features
Last modified by Scott Kohlmann on 2023/04/21 15:15
From version 4.2
edited by Mark Kohlmann
on 2022/10/14 18:39
on 2022/10/14 18:39
Change comment:
There is no comment for this version
To version 5.1
edited by Mark Kohlmann
on 2022/10/14 23:43
on 2022/10/14 23:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,4 +1,4 @@ 1 - SHOWRUNNER™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market.1 +showrunner™ has a large number of features focused on the needs of the commercial lighting and hospitality markets and is adaptable to the residential market. Hardware support is extensive and growing all the time. 2 2 3 3 ==== Area Features ==== 4 4 ... ... @@ -6,6 +6,7 @@ 6 6 * Scene recall 7 7 * Master raise/lower 8 8 * User configurable scene name, fade time, and load include by scene 9 +* Individual scenes may be locked to prevent changing their settings 9 9 * Individual load control within an area 10 10 * Select area from touchpanel, areas can be restricted by panel 11 11 * RGB controls for applicable fixtures, saved per scene ... ... @@ -14,7 +14,6 @@ 14 14 ** CCT Control per area for applicable fixtures 15 15 ** Global schedule for CCT, astronomical and/or fixed schedules 16 16 ** Manual CCT override per area 17 -** Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 18 18 * Demand Response with ability to exclude area from Demand Response event 19 19 * Configurable load grouping allows aggregation of loads to a single slider per group, can include linked areas 20 20 * HVAC Control ... ... @@ -31,6 +31,7 @@ 31 31 * After Hours support for automatic shutoff after configurable timeout w/ alerting 32 32 * Parent Area feature allows one area to trickle down scene recall and raise/lower (if enabled) 33 33 * Last Scene Recall timestamp and triggering action recorded 34 +* Organized in a node tree with multiple depths 34 34 35 35 ==== Load Features ==== 36 36 ... ... @@ -134,13 +134,37 @@ 134 134 *** Enable/Disable 135 135 ** Pre-loaded with US Federal and common non-Federal US Holidays 136 136 137 -=== Supported HardwareFeatures===138 +==== Circadian Rhythm/Dynamic White ==== 138 138 140 +* Global system CCT Level 141 +* Override CCT per area by scene or manually 142 +* Crestron GLS-LCCT (SolarSync™) sensor integration for daylight tracking 143 +* Time period based 144 +** Time References for start and end of period 145 +*** AM/PM 146 +*** Relative to 147 +**** Sunrise 148 +**** Sunset 149 +**** Solar Noon 150 +** Each time period can have the following setting for CCT 151 +*** Static 152 +*** Linear change over time 153 +*** Sensor with configured CCT when sensor is out of range 154 +* Supported with 0-10V, DMX, and DALI 155 + 156 +==== Supported Hardware Features ==== 157 + 158 +Virtually the entire Crestron lighting product line is supported along with several 3rd party products 159 + 139 139 * Common Settings to all devices 140 140 ** Contractor Label 141 141 ** Name 142 142 ** GlobalId 143 143 ** UniqueId (GUID) 165 +* HVAC 166 +** Temperature control by area 167 +** Support for some Crestron Thermostats, more can be added as needed 168 +** Support for some 3rd party systems, more can be added as needed 144 144 * Keypads 145 145 ** Support for common fixed configurations, user assignable at runtime 146 146 ** Custom keypads with configurable actions per button at runtime ... ... @@ -160,7 +160,7 @@ 160 160 ** Configurable double tap time support if supported by hardware 161 161 ** Simulate keypads from showrunner™ HUB UI or console 162 162 ** Direct load mapping for some common keypads 163 -* Keyswitch andContact Closure Inputs188 +* Keyswitch/Contact Closure Inputs 164 164 ** Supports all versiport and digital inputs 165 165 ** Maintained and Momentary supported 166 166 ** Feedback output supported ... ... @@ -178,6 +178,12 @@ 178 178 ** User configurable assignment of sensor to area(s) and load(s) 179 179 ** Occupancy sensors may feed data to multiple areas and loads 180 180 ** Last occupied and vacant times recorded 206 +* Output Signal 207 +** Logic object capable of triggering additional logic 208 +** Can trigger physical outputs via versiports/IOs 209 +** Supports conditional logic 210 +** Independent actions for active/inactive states 211 +** Configurable delays for active/inactive execution 181 181 * Partition sensors 182 182 ** Support for divisible areas 183 183 ** GLS-PART-CN with adjustable sensitivity ... ... @@ -185,12 +185,25 @@ 185 185 ** User configurable Auto, Combined, and Divided 186 186 ** Filtering to ignore noisy partition sensors 187 187 ** Change count and last change recorded 219 +* Photocell 220 +** Supports Open Loop, Closed Loop, Exterior, and LCCT (as SolarSync™ and exterior) 221 +** Configurable coefficient 222 +** Configurable thresholds 223 +** Assignable to individual loads for daylight harvesting 224 +* Serial Interface 225 +** RS-232/422/484 226 +** Configurable Baud Rate and Com settings 227 +** Simple ASCII API for controlling/montioring 228 +** Areas/Loads/Occupancy/Partition/Shades supported 229 +* Shades 230 +** Support for Crestron shades/drapes 231 +** Support for many 3rd party shade and drape systems 188 188 189 189 ==== Energy Efficiency ==== 190 190 191 191 * Demand Response/Load Shedding 192 192 ** Automatic via sensor input 193 -** Manually via keypad237 +** Manually via user input 194 194 * Calculated or Measured Power (Watts) 195 195 * Energy Efficiency visualization on floorplan 196 196 ... ... @@ -207,39 +207,139 @@ 207 207 ** Login via username/password or PIN code 208 208 ** Support for Processor or internal user database 209 209 ** Best practices for password handling 210 -* API Usersusing AWSv4 scheme for authentication per request for maximum security254 +* API using AWSv4 scheme for authentication per request for maximum security 211 211 212 -==== System Settings ====256 +==== System Features ==== 213 213 214 214 * User configurable time zone, location, and current time 215 215 * Addressing and Verification of Cresnet devices by serial number 216 216 * Cresnet Device Serial Number capture 217 217 * Configurable Global Actions with touchpanel trigger 218 -* Remote hardware support from neighbor ShowRunner System: 219 -** Allows a master ShowRunner system to integrate slave processors 220 -** AV Serial Interface 221 -** Loads 222 -** Controllers 223 -** Keypad 224 -** Keyswitches 225 -** Occupancy Sensor (including setup for Cresnet sensors) 226 -** Partition Sensors (including setup for Cresnet sensors) 227 -** Photocells 228 -* Web based reporting directly from the processor allows generation of as built documentation: Cresnet Discovery, Device Status, Event Schedule, Keypad Schedule, Load Schedule, and Panel Schedule 262 +* Extensive console command interface (CLI) 229 229 264 +(% class="wikigeneratedid" %) 265 +==== Extensibility ==== 266 + 267 +* Actions 268 +** Logic objects exist on showrunner™ objects 269 +** Functionality can be triggered via APIs 270 +** Used for defining the behaviors of global actions, custom keypads, and numerous other logic operations within showrunner™ 271 +* Extensions 272 +** Extension model allows customization and additional functionality to be added to the showrunner™ ecosystem 273 +** [[Supported functions>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.Extensions.WebHome]] 274 +* Global Actions 275 +** Allow minimal or input triggered operations against the system 276 +** Can be custom programmed at runtime 277 + 278 +==== User Interfaces ==== 279 + 280 +* showrunner™ HUB 281 +** Web based 282 +** Runs directly on the processor or VC-4 instance 283 +** HTTPS required 284 +** Can be run in kiosk mode on a touchscreen PC for the full touchscreen experience 285 +** Node Tree 286 +*** Organize areas in logical locations based on physical topology 287 +*** Searchable, only shows matching areas 288 +** Floorplans 289 +*** Assigned to a node, multiple floor plans are supported 290 +*** Pinch zoom/touch pan 291 +*** User provided floorplan 292 +*** Draw directly on floorplan for areas and objects 293 +**** Areas 294 +**** Loads 295 +**** Partitions 296 +**** Occupancy Sensors 297 +**** Keypads 298 +**** Photocells 299 +*** Crestron product line icons area available to match the installed sensor 300 +*** Interactive control screens depending on clicked object 301 +*** Multiple different views help visualize data 302 +**** Area View - Shows areas with user selected colors 303 +**** Tags View - Shows areas based on their assigned tag 304 +**** Occupancy View - Shows areas based on their current occupancy status and how recently that status changed 305 +**** Intensity View - Shows areas shaded based on the current overall light intensity 306 +**** Energy View - Shows areas shaded based on the areas current energy efficiency from efficient to inefficient 307 +*** Automatic navigation to area when selected from the node tree 308 +*** Fullscreen view 309 +** Schedule 310 +*** See [[Scheduling Features>>doc:||anchor="Scheduling Features"]] for more info 311 +** Reports 312 +*** Interactive data 313 +**** Area Loads 314 +**** Area Scenes 315 +**** Areas 316 +**** Cresnet (Query) 317 +**** Device Status 318 +**** Events 319 +**** Keypads 320 +** Setup 321 +*** Device Diagnostic - Show Diagnostic data from supported devices 322 +*** Hardware Management - Tree view of Ethernet, Cresnet, and RF topologies 323 +*** File Management - Manage config, license, currently active config, and backup/restore operations 324 +*** Global Actions - Add/Delete/Configure 325 +*** Integrations - Manage integrations with other showrunner™ systems 326 +*** Keypad Configuration - Configure keypads 327 +*** Maps - Add floorplan images 328 +*** Network - DHCP Server (for processors without routers only) 329 +*** System Settings - Manage various system settings 330 +*** Tags - Manage tags and association of tags with areas 331 +*** User Management - Manage users/groups/API users 332 +* Crestron TS/TSWs and Crestron App (iPad/iPhone/Android) 333 + 230 230 === Integrations === 231 231 232 232 * AV Integration protocol via serial port 233 -* BACNET Support for integration of Areas, Loads (Licensed Feature) 337 +* BACNnet Support for integration of Areas, Loads (Licensed Feature, both showrunner and Crestron) 338 +** Global 339 +*** Override 340 +*** Demand Response 341 +*** Device Offline Count 342 +*** Alarm 343 +*** System Normal/After Hours 344 +** Area Specific 345 +*** showrunner™ Mode 346 +**** Occupancy Status 347 +**** Occupancy Enable 348 +**** Scenes 349 +**** Loads 350 +**** Photocell Level 351 +**** Overall Intensity 352 +**** Power (watts) 353 +*** Zum Hub Emulation Mode 354 +**** Online 355 +**** On 356 +**** Scenes 357 +**** Occupied 358 +**** Occupancy Sensor Enable 234 234 * Crestron Fusion (Licensed Feature) 360 +** Scenes, Recall and Save 361 +** Load Control 362 +** Occupancy Status 363 +** Photocell 235 235 * E-DMX Receiver 236 -** SACN or Art-Net 237 -** Enable/Disable control for loads 365 +** SACN and/or Art-Net 366 +** Enable/Disable control for loads using e-DMX channel value 238 238 ** Map DMX to showrunner loads 239 239 * EISC Export for AV Integration, dynamic creation from the UI (3-series, classic, EISC Client, EISC Server, VC-4 Client) 369 +** Configurable IP address and IP-ID, change at runtime 370 +** Configurable rooms to export, change at runtime 371 +** Changes generate new RSD file at runtime that may be provided to the AV programmer 240 240 * HTTP REST API w/ Authorization 241 241 * Lightweight API provides real-time control/feedback of hardware using CoAP 374 +* TCP Interface using simple ASCII commands, subscriptions supported 375 +* UDP Receiver using simple ASCII commands 242 242 * Zum Floor Hub Support for integration, Export showrunner™ areas to the Floor Hub (Licensed Feature) 377 +* Remote hardware support from neighbor ShowRunner System: 378 +** Allows a central ShowRunner system to integrate edge processors 379 +** AV Serial Interface 380 +** Loads 381 +** Controllers 382 +** Keypad 383 +** Keyswitches 384 +** Occupancy Sensor (including setup for Cresnet sensors) 385 +** Partition Sensors (including setup for Cresnet sensors) 386 +** Photocells 243 243 244 244 === Reporting === 245 245