Changes for page Resolving Custom Logo Not Loading on Touchscreens with Authentication on Processor Enabled
Last modified by Scott Kohlmann on 2023/04/21 15:09
From version 5.1
edited by Scott Kohlmann
on 2023/04/21 15:09
on 2023/04/21 15:09
Change comment:
There is no comment for this version
To version 3.1
edited by Alexander Mott
on 2022/03/15 18:43
on 2022/03/15 18:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. scott\.kohlmann@chiefintegrations\.com1 +XWiki.alexander\.mott@chiefintegrations\.com - Content
-
... ... @@ -1,4 +1,4 @@ 1 -Crestron 3-series processors with authentication enabled* or 4-series processors with User Page Authentication enabled will require a username and password to obtain the custom logo hosted by the processor's internal web server. ShowRunner CLC™ version 3.010 introduces the ability to pass the credentials to the touchpanel as part of the URL. This article shows the steps necessary to enable this feature.1 +Crestron 3-series processors with authentication enabled* or 4-series processors with User Page Authentication enabled will require a username and password to obtain the custom logo hosted by the processor's internal web server. ShowRunner™ version 3.010 introduces the ability to pass the credentials to the touchpanel as part of the URL. This article shows the steps necessary to enable this feature. 2 2 3 3 * Connect to the processor's console via SSH with a user with admin rights on the processor. 4 4 * Enter "##sradmin create sradmin user (Username) (Password)##" where Username and Password are the credentials for a user with admin rights on the processor. ... ... @@ -19,4 +19,4 @@ 19 19 20 20 If the custom logo still does not show on the touchscreen, it may be due to certificate issues. To resolve certificate errors, see [[here>>doc:SHOWRUNNER™ User Guide & Wiki.SHOWRUNNER™ Appendix.Resolving Certificate Errors on Touchscreens.WebHome]]. 21 21 22 -~* As of 3/1/2022, Crestronfirmware version 1.8001.0133 now enables User Page Authentication to be disabled on 3-Series processors using the command "##userpageauth off##", allowing Touchscreens to access custom logo files without creating these users.22 +~* As of 3/1/2022, firmware version 1.8001.0133 now enables User Page Authentication to be disabled on 3-Series processors using the command "##userpageauth off##", allowing Touchscreens to access custom logo files without creating these users.