Changes for page Zūm Wired Wiring Overview
Last modified by Alexander Mott on 2024/03/01 18:46
From version 67.1
edited by Alexander Mott
on 2024/01/05 18:46
on 2024/01/05 18:46
Change comment:
There is no comment for this version
To version 61.1
edited by Alexander Mott
on 2022/09/17 00:43
on 2022/09/17 00:43
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,25 +1,22 @@ 1 -(% class="row" %) 2 -((( 3 -(% class="col-xs-12 col-sm-8" %) 4 -((( 5 -(% class="box errormessage" %) 6 -((( 7 -All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues. 8 -))) 1 +{{box title="**CONTENTS**"}} 2 +{{toc/}} 3 +{{/box}} 9 9 10 10 (% class="row" %) 11 11 ((( 12 12 (% class="col-xs-12 col-sm-8" %) 13 13 ((( 14 - ZūmWired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware.It uses industry standard 0-10V, phase dimming, and DALI protocols to allow for automated control of a building's lighting.9 += Overview = 15 15 16 - AZūm Wired systemconsistsofseveraldevices thatare joinedonthree distinct networksthat eachuse thesamecables andconnectors asEthernet.ThethreenetworksinaZūm Wiredystemare:11 +Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, DMX, and DALI protocols to allow for automated control of a building's lighting. 17 17 13 +A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system that adhere to Ethernet standards are: 14 + 18 18 * Ethernet 19 19 * Zūm Net 20 20 * Zūm Link 21 21 22 -Additionally, traditional 4-wire Cresnet can be wired directly into a Zūm Link network; [[wiring details below>> SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HZ16BmLinktoCresnet"]].19 +Additionally, traditional 4-wire Cresnet can be wired directly into a Zūm Link network; [[wiring details below>>WebHome||anchor="HZ16BmLinktoCresnet"]]. 23 23 24 24 = Ethernet = 25 25 ... ... @@ -29,13 +29,13 @@ 29 29 30 30 Zūm Net wiring should adhere to Ethernet cabling standards and use standard RJ-45 connectors. Zūm Net connects networked room-level controllers throughout the building to each other and to the lighting network. Each Zūm Net run will typically originate at a Hub or Processor panel and then connect to a number of ZUMNET-JBOX devices. 31 31 32 -Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable is shown in purple on //[[Figure 1>> SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices.29 +Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable is shown in purple on //[[Figure 1>>WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices. 33 33 34 34 ZUMNET-JBOX devices are covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome]]. 35 35 36 36 = Zūm Link = 37 37 38 -Zūm Link runs originate at a ZUMNET-JBOX and connect various Zūm Link devices within a room to the ZUMNET-JBOX for that room. Zūm Link cable is shown in orange on //[[Figure 1>> SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm Net devices. Additionally, **do not loop Zūm Link runs back to a Zūm Net device**; each Zūm Link run should originate at an orange Zūm Link port on a Zūm Net device and end at the last Zūm Link device on the run.35 +Zūm Link runs originate at a ZUMNET-JBOX and connect various Zūm Link devices within a room to the ZUMNET-JBOX for that room. Zūm Link cable is shown in orange on //[[Figure 1>>WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm Net devices. Additionally, **do not loop Zūm Link runs back to a Zūm Net device**; each Zūm Link run should originate at an orange Zūm Link port on a Zūm Net device and end at the last Zūm Link device on the run. 39 39 40 40 Links to articles covering specific Zūm Link devices can be found [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.WebHome]]. 41 41 ... ... @@ -58,28 +58,22 @@ 58 58 |(% style="width:87px" %)7|(% style="width:213px" %)Cresnet Y (Data +)|(% style="width:257px" %)White|(% style="width:426px" %)White / Brown 59 59 |(% style="width:87px" %)8|(% style="width:213px" %)Cresnet Z (Data -)|(% style="width:257px" %)Blue|(% style="width:426px" %)Brown 60 60 61 -//[[Figure 2>> SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HFigure2"]]// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]].58 +//[[Figure 2>>WebHome||anchor="HFigure2"]]// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]]. 62 62 ))) 63 63 64 64 65 65 (% class="col-xs-12 col-sm-4" %) 66 66 ((( 67 -{{box title="**CONTENTS**"}} 68 -{{toc/}} 69 -{{/box}} 70 - 71 71 (% class="wikigeneratedid" id="HFigure1" %) 72 72 ((( 73 73 [[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]] 74 -//Figure 1: Overview of a typical Zūm Wired system [[(larger)>> attach:wiki_zumwired67 +//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.2]]// 75 75 ))) 76 76 77 77 (% class="wikigeneratedid" id="HFigure2" %) 78 78 ((( 79 79 [[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]] 80 -//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>> attach:wiki_zumlink73 +//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.// 81 81 ))) 82 82 ))) 83 83 ))) 84 -))) 85 -)))