Changes for page Zūm Wired Wiring Overview
Last modified by Alexander Mott on 2024/03/01 18:46
From version 65.1
edited by Alexander Mott
on 2024/01/05 16:37
on 2024/01/05 16:37
Change comment:
There is no comment for this version
To version 62.1
edited by Alexander Mott
on 2022/09/19 16:20
on 2022/09/19 16:20
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -2,19 +2,10 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -(% class="box errormessage" %) 6 -((( 7 -All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues. 8 -))) 5 +Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, DMX, and DALI protocols to allow for automated control of a building's lighting. 9 9 10 -(% class="row" %) 11 -((( 12 -(% class="col-xs-12 col-sm-8" %) 13 -((( 14 -Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, and DALI protocols to allow for automated control of a building's lighting. 7 +A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system that adhere to Ethernet standards are: 15 15 16 -A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system are: 17 - 18 18 * Ethernet 19 19 * Zūm Net 20 20 * Zūm Link ... ... @@ -71,15 +71,13 @@ 71 71 (% class="wikigeneratedid" id="HFigure1" %) 72 72 ((( 73 73 [[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]] 74 -//Figure 1: Overview of a typical Zūm Wired system [[(larger)>> attach:wiki_zumwired65 +//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.2]]// 75 75 ))) 76 76 77 77 (% class="wikigeneratedid" id="HFigure2" %) 78 78 ((( 79 79 [[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]] 80 -//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>> attach:wiki_zumlink71 +//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.// 81 81 ))) 82 82 ))) 83 83 ))) 84 -))) 85 -)))