Changes for page Zūm Wired Wiring Overview
Last modified by Alexander Mott on 2024/03/01 18:46
From version 65.1
edited by Alexander Mott
on 2024/01/05 16:37
on 2024/01/05 16:37
Change comment:
There is no comment for this version
To version 11.1
edited by Alexander Mott
on 2021/12/21 23:16
on 2021/12/21 23:16
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 2 added, 2 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Zūm Wired 1 +*Zūm Wired - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.WebHome1 +Wiring Guide.Wiring Overview.WebHome - Content
-
... ... @@ -1,85 +1,49 @@ 1 -(% class="row" %) 2 -((( 3 -(% class="col-xs-12 col-sm-8" %) 4 -((( 5 -(% class="box errormessage" %) 6 -((( 7 -All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues. 8 -))) 1 +{{box title="**Contents**"}} 2 +{{toc/}} 3 +{{/box}} 9 9 10 10 (% class="row" %) 11 11 ((( 12 12 (% class="col-xs-12 col-sm-8" %) 13 13 ((( 14 -Zūm Wired is a distributed lighting control systemmanufactured by Crestron thatis set to replace the older Cresnet-based GLPP hardware.It uses industry standard 0-10V, phase dimming, and DALI protocols to allow for automated control of a building's lighting.9 += Zūm Wired System Overview = 15 15 16 - AZūm Wired systemconsistsofseveraldeviceshat are joined on threedistinctnetworksthateach use thesamecablesand connectorsasEthernet.The threenetworks in aZūmWiredsystemare:11 +Zūm Wired is a distributed lighting control system manufactured and distributed by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, DMX, and DALI protocols to allow for automated control of a building's lighting. 17 17 18 -* Ethernet 13 +A Zūm Wired system consists of three distinct networks, which each use the same cabling but which serves different purposes.: 14 + 19 19 * Zūm Net 20 20 * Zūm Link 17 +* Ethernet 21 21 22 - Additionally,traditional 4-wire Cresnet can be wired directly into aZūmLink network;[[wiring details below>>WebHome||anchor="HZ16BmLinktoCresnet"]].19 +== Zūm Net == 23 23 24 - =Ethernet=21 +Zūm Net devices 25 25 26 - Ethernet providesthebackbone of the lighting network.Ethernet joins the Hub panels to each other, the processor, and (if the design calls for it) the building LAN. All Ethernet cabling should adhere to the [[Ethernet standards>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] for Crestron systems.23 +== Zūm Link == 27 27 28 - = Zūm Net =25 +Lo 29 29 30 - ZūmNet wiring should adhere to Ethernet cabling standards and use standard RJ-45 connectors.ZūmNet connects networked room-level controllers throughout the building to each other and to the lighting network.Each Zūm Netrun will typicallyoriginateat a Hub orProcessor panel andthenconnect to a number of ZUMNET-JBOX devices.27 +=== Zūm Link to Cresnet === 31 31 32 - Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable is shown in purple on //[[Figure 1>>WebHome||anchor="HFigure1"]]//. **It is very important to never connect a ZūmLink cable to a Zūm Net port** as this may damage the Zūm net devices.29 +L 33 33 34 - ZUMNET-JBOX devicesarecovered inmoredetail [[here>>doc:SHOWRUNNER™ Setup Guide.WiringGuide.Zūm Wired System Overview.Load Controllers(ZUMNET-JBOX).WebHome]].31 +=== Non-System Sensor Integration === 35 35 36 - = ZūmLink =33 +L 37 37 38 - ZūmLink runs originate at a ZUMNET-JBOX and connectvarious Zūm Link devices within a room to theZUMNET-JBOX forthat room. Zūm Link cableis shown in orange on //[[Figure 1>>WebHome||anchor="HFigure1"]]//. **Itis very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm Net devices. Additionally, **do not loop Zūm Link runs back to a Zūm Net device**; each Zūm Link run should originate at an orange Zūm Link port on a Zūm Net device and end at the last Zūm Link device on the run.35 +== Ethernet == 39 39 40 -Links to articles covering specific Zūm Link devices can be found [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.WebHome]]. 41 - 42 -== Zūm Link to Cresnet == 43 - 44 -While most Zūm Link wiring will adhere to Ethernet cabling standards and utilize standard RJ-45 connectors, Zūm Link is not technically Ethernet. In some situations, it may be necessary to wire traditional Cresnet devices into a Zūm Link space. 45 - 46 -In the future, Crestron will be producing a ZUMLINK-CNRJ45 adapter to allow for plug-and-play connections between Zūm Link RJ-45 connectors and 4-wire Cresnet devices. Until this product is available however, it is necessary to strip the Zūm Link wire and terminate it directly into a Cresnet phoenix connector or terminal block. 47 - 48 -The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the [[T568B Standard>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome||anchor="HFigure1"]] is as follows: 49 - 50 -(% border="1" style="margin-right:auto" %) 51 -|=(% style="width: 87px;" %)RJ-45 Pin|=(% style="width: 213px;" %)Function|=(% style="width: 257px;" %)Cresnet Color|=(% style="width: 426px;" %)T568-B Color 52 -|(% style="width:87px" %)1|(% style="width:213px" %)24V|(% colspan="1" rowspan="2" style="width:257px" %)Red|(% style="width:426px" %)White / Orange 53 -|(% style="width:87px" %)2|(% style="width:213px" %)24V|(% style="width:426px" %)Orange 54 -|(% style="width:87px" %)3|(% style="width:213px" %)GND|(% colspan="1" rowspan="2" style="width:257px" %)Black|(% style="width:426px" %)White / Green 55 -|(% style="width:87px" %)4|(% style="width:213px" %)GND|(% style="width:426px" %)Blue 56 -|(% style="width:87px" %)5|(% colspan="1" style="width:213px" %)(N/C)|(% colspan="1" style="width:257px" %)(N/C)|(% style="width:426px" %)White / Blue 57 -|(% style="width:87px" %)6|(% colspan="1" style="width:213px" %)(N/C)|(% colspan="1" style="width:257px" %)(N/C)|(% style="width:426px" %)Green 58 -|(% style="width:87px" %)7|(% style="width:213px" %)Cresnet Y (Data +)|(% style="width:257px" %)White|(% style="width:426px" %)White / Brown 59 -|(% style="width:87px" %)8|(% style="width:213px" %)Cresnet Z (Data -)|(% style="width:257px" %)Blue|(% style="width:426px" %)Brown 60 - 61 -//[[Figure 2>>WebHome||anchor="HFigure2"]]// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]]. 37 +L 62 62 ))) 63 63 64 64 65 65 (% class="col-xs-12 col-sm-4" %) 66 66 ((( 67 -{{box title="**CONTENTS**"}} 68 -{{toc/}} 69 -{{/box}} 43 +[[image:wiki_zumwired trans.png]] 44 +//Figure 1: [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.1]]// 70 70 71 -(% class="wikigeneratedid" id="HFigure1" %) 72 -((( 73 -[[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]] 74 -//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>attach:wiki_zumwired trans.png]]// 46 +[[image:Templates.Article.Template.WebHome@image2.jpg]] 47 +//Figure 2: [[Waves>>https://commons.wikimedia.org/wiki/File:Culebra_-_Playa_de_Flamenco.jpg]]// 75 75 ))) 76 - 77 -(% class="wikigeneratedid" id="HFigure2" %) 78 -((( 79 -[[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]] 80 -//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>attach:wiki_zumlink to cresnet.png]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.// 81 81 ))) 82 -))) 83 -))) 84 -))) 85 -)))
- 1640284131125-244.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.8 KB - Content
- wiki_zumlink to cresnet.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -759.1 KB - Content
- image1.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.MarkKohlmann - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.8 KB - Content
- image2.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.MarkKohlmann - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.0 KB - Content