Last modified by Alexander Mott on 2024/03/01 18:46

From version 62.1
edited by Alexander Mott
on 2022/09/19 16:20
Change comment: There is no comment for this version
To version 70.3
edited by Alexander Mott
on 2024/01/05 18:52
Change comment: Renamed from xwiki:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Zūm Wired
1 +Zūm Wired Wiring Overview
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.WebHome
1 +xwiki:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.WebHome
Content
... ... @@ -2,10 +2,19 @@
2 2  (((
3 3  (% class="col-xs-12 col-sm-8" %)
4 4  (((
5 -Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, DMX, and DALI protocols to allow for automated control of a building's lighting.
5 +(% class="box errormessage" %)
6 +(((
7 +All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues.
8 +)))
6 6  
7 -A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system that adhere to Ethernet standards are:
10 +(% class="row" %)
11 +(((
12 +(% class="col-xs-12 col-sm-8" %)
13 +(((
14 +Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, and DALI protocols to allow for automated control of a building's lighting.
8 8  
16 +A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system are:
17 +
9 9  * Ethernet
10 10  * Zūm Net
11 11  * Zūm Link
... ... @@ -14,7 +14,7 @@
14 14  
15 15  = Ethernet =
16 16  
17 -Ethernet provides the backbone of the lighting network. Ethernet joins the Hub panels to each other, the processor, and (if the design calls for it) the building LAN. All Ethernet cabling should adhere to the [[Ethernet standards>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] for Crestron systems.
26 +Ethernet provides the backbone of the lighting network. Ethernet joins the Hub panels to each other, the processor, and (if the design calls for it) the building LAN. All Ethernet cabling should adhere to the [[Ethernet standards>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.Ethernet Wiring Overview.WebHome]] for Crestron systems.
18 18  
19 19  = Zūm Net =
20 20  
... ... @@ -36,7 +36,7 @@
36 36  
37 37  In the future, Crestron will be producing a ZUMLINK-CNRJ45 adapter to allow for plug-and-play connections between Zūm Link RJ-45 connectors and 4-wire Cresnet devices. Until this product is available however, it is necessary to strip the Zūm Link wire and terminate it directly into a Cresnet phoenix connector or terminal block.
38 38  
39 -The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the [[T568B Standard>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome||anchor="HFigure1"]] is as follows:
48 +The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the [[T568B Standard>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.Ethernet Wiring Overview.WebHome||anchor="HFigure1"]] is as follows:
40 40  
41 41  (% border="1" style="margin-right:auto" %)
42 42  |=(% style="width: 87px;" %)RJ-45 Pin|=(% style="width: 213px;" %)Function|=(% style="width: 257px;" %)Cresnet Color|=(% style="width: 426px;" %)T568-B Color
... ... @@ -62,13 +62,15 @@
62 62  (% class="wikigeneratedid" id="HFigure1" %)
63 63  (((
64 64  [[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]]
65 -//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.2]]//
74 +//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>attach:wiki_zumwired trans.png]]//
66 66  )))
67 67  
68 68  (% class="wikigeneratedid" id="HFigure2" %)
69 69  (((
70 70  [[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]]
71 -//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.//
80 +//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>attach:wiki_zumlink to cresnet.png]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.//
72 72  )))
73 73  )))
74 74  )))
84 +)))
85 +)))