Content
... ... @@ -1,17 +1,20 @@
1 -{{box title="**CONTENTS**"}}
2 -{{toc/}}
3 -{{/box}}
1 +(% class="row" %)
2 +(((
3 +(% class="col-xs-12 col-sm-8" %)
4 +(((
5 +(% class="box errormessage" %)
6 +(((
7 +All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues.
8 +)))
4 4  
5 5  (% class="row" %)
6 6  (((
7 7  (% class="col-xs-12 col-sm-8" %)
8 8  (((
9 -= Overview =
14 +Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, and DALI protocols to allow for automated control of a building's lighting.
10 10  
11 -Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, DMX, and DALI protocols to allow for automated control of a building's lighting.
16 +A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system are:
12 12  
13 -A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system that adhere to Ethernet standards are:
14 -
15 15  * Ethernet
16 16  * Zūm Net
17 17  * Zūm Link
... ... @@ -61,16 +61,22 @@
61 61  
62 62  (% class="col-xs-12 col-sm-4" %)
63 63  (((
67 +{{box title="**CONTENTS**"}}
68 +{{toc/}}
69 +{{/box}}
70 +
64 64  (% class="wikigeneratedid" id="HFigure1" %)
65 65  (((
66 66  [[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]]
67 -//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.2]]//
74 +//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>attach:wiki_zumwired trans.png]]//
68 68  )))
69 69  
70 70  (% class="wikigeneratedid" id="HFigure2" %)
71 71  (((
72 72  [[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]]
73 -//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.//
80 +//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>attach:wiki_zumlink to cresnet.png]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.//
74 74  )))
75 75  )))
76 76  )))
84 +)))
85 +)))