Changes for page Zūm Wired Wiring Overview
Last modified by Alexander Mott on 2024/03/01 18:46
From version 5.1
edited by Alexander Mott
on 2021/12/20 21:25
on 2021/12/20 21:25
Change comment:
There is no comment for this version
To version 64.1
edited by Alexander Mott
on 2024/01/05 16:31
on 2024/01/05 16:31
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 2 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - *Zūm Wired1 +Zūm Wired - Parent
-
... ... @@ -1,1 +1,1 @@ 1 -Wiring Guide.Wiring Overview.WebHome 1 +SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.WebHome - Content
-
... ... @@ -2,42 +2,84 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -= Zūm Wired System Overview = 5 +(% class="box errormessage" %) 6 +((( 7 +All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues. 8 +))) 6 6 7 -Zūm Wired is a distributed lighting control system manufactured and distributed by Crestron. It uses industry standard 0-10V, DMX, DALI, and phase dimming control protocols to 10 +(% class="row" %) 11 +((( 12 +(% class="col-xs-12 col-sm-8" %) 13 +((( 14 +Zūm Wired is a distributed lighting control system manufactured by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, and DALI protocols to allow for automated control of a building's lighting. 8 8 9 - ==ZūmNet==16 +A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectors as Ethernet. The three networks in a Zūm Wired system are: 10 10 11 -Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum. 18 +* Ethernet 19 +* Zūm Net 20 +* Zūm Link 12 12 13 - ==Zūm Link ==22 +Additionally, traditional 4-wire Cresnet can be wired directly into a Zūm Link network; [[wiring details below>>WebHome||anchor="HZ16BmLinktoCresnet"]]. 14 14 15 - Loremipsum dolor sitamet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit involuptatevelitesse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.24 += Ethernet = 16 16 17 - ===ZūmLink toCresnet===26 +Ethernet provides the backbone of the lighting network. Ethernet joins the Hub panels to each other, the processor, and (if the design calls for it) the building LAN. All Ethernet cabling should adhere to the [[Ethernet standards>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome]] for Crestron systems. 18 18 19 - Loremipsumdolor sit amet,consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum.28 += Zūm Net = 20 20 21 - ===Non-SystemSensorIntegration===30 +Zūm Net wiring should adhere to Ethernet cabling standards and use standard RJ-45 connectors. Zūm Net connects networked room-level controllers throughout the building to each other and to the lighting network. Each Zūm Net run will typically originate at a Hub or Processor panel and then connect to a number of ZUMNET-JBOX devices. 22 22 23 - Lorem ipsum dolor sitamet,consecteturadipiscingelit,sed do eiusmodtempor incididunt utlabore etdoloremagna aliqua.Utenimad minim veniam,quisnostrudexercitation ullamcolaborisnisiut aliquipexea commodo consequat. Duis aute iruredolorinreprehenderitin voluptatevelit esse cillum doloreeu fugiatnullapariatur.Excepteursintccaecatcupidatat non proident,suntinculpaqui officiadeserunt mollitanimidt laborum.32 +Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable is shown in purple on //[[Figure 1>>WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices. 24 24 25 - ==Ethernet==34 +ZUMNET-JBOX devices are covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome]]. 26 26 27 -Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum. 36 += Zūm Link = 37 + 38 +Zūm Link runs originate at a ZUMNET-JBOX and connect various Zūm Link devices within a room to the ZUMNET-JBOX for that room. Zūm Link cable is shown in orange on //[[Figure 1>>WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm Net devices. Additionally, **do not loop Zūm Link runs back to a Zūm Net device**; each Zūm Link run should originate at an orange Zūm Link port on a Zūm Net device and end at the last Zūm Link device on the run. 39 + 40 +Links to articles covering specific Zūm Link devices can be found [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Zūm Wired System Overview.WebHome]]. 41 + 42 +== Zūm Link to Cresnet == 43 + 44 +While most Zūm Link wiring will adhere to Ethernet cabling standards and utilize standard RJ-45 connectors, Zūm Link is not technically Ethernet. In some situations, it may be necessary to wire traditional Cresnet devices into a Zūm Link space. 45 + 46 +In the future, Crestron will be producing a ZUMLINK-CNRJ45 adapter to allow for plug-and-play connections between Zūm Link RJ-45 connectors and 4-wire Cresnet devices. Until this product is available however, it is necessary to strip the Zūm Link wire and terminate it directly into a Cresnet phoenix connector or terminal block. 47 + 48 +The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the [[T568B Standard>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome||anchor="HFigure1"]] is as follows: 49 + 50 +(% border="1" style="margin-right:auto" %) 51 +|=(% style="width: 87px;" %)RJ-45 Pin|=(% style="width: 213px;" %)Function|=(% style="width: 257px;" %)Cresnet Color|=(% style="width: 426px;" %)T568-B Color 52 +|(% style="width:87px" %)1|(% style="width:213px" %)24V|(% colspan="1" rowspan="2" style="width:257px" %)Red|(% style="width:426px" %)White / Orange 53 +|(% style="width:87px" %)2|(% style="width:213px" %)24V|(% style="width:426px" %)Orange 54 +|(% style="width:87px" %)3|(% style="width:213px" %)GND|(% colspan="1" rowspan="2" style="width:257px" %)Black|(% style="width:426px" %)White / Green 55 +|(% style="width:87px" %)4|(% style="width:213px" %)GND|(% style="width:426px" %)Blue 56 +|(% style="width:87px" %)5|(% colspan="1" style="width:213px" %)(N/C)|(% colspan="1" style="width:257px" %)(N/C)|(% style="width:426px" %)White / Blue 57 +|(% style="width:87px" %)6|(% colspan="1" style="width:213px" %)(N/C)|(% colspan="1" style="width:257px" %)(N/C)|(% style="width:426px" %)Green 58 +|(% style="width:87px" %)7|(% style="width:213px" %)Cresnet Y (Data +)|(% style="width:257px" %)White|(% style="width:426px" %)White / Brown 59 +|(% style="width:87px" %)8|(% style="width:213px" %)Cresnet Z (Data -)|(% style="width:257px" %)Blue|(% style="width:426px" %)Brown 60 + 61 +//[[Figure 2>>WebHome||anchor="HFigure2"]]// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.Cresnet.WebHome]]. 28 28 ))) 29 29 30 30 31 31 (% class="col-xs-12 col-sm-4" %) 32 32 ((( 33 -{{box title="**C ontents**"}}67 +{{box title="**CONTENTS**"}} 34 34 {{toc/}} 35 35 {{/box}} 36 36 37 -[[image:Templates.Article.Template.WebHome@image1.jpg]] 38 -//Figure 1: [[Sea>>https://commons.wikimedia.org/wiki/File:Isle_of_Icacos_II.jpg]]// 71 +(% class="wikigeneratedid" id="HFigure1" %) 72 +((( 73 +[[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]] 74 +//Figure 1: Overview of a typical Zūm Wired system [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.2]]// 75 +))) 39 39 40 -[[image:Templates.Article.Template.WebHome@image2.jpg]] 41 -//Figure 2: [[Waves>>https://commons.wikimedia.org/wiki/File:Culebra_-_Playa_de_Flamenco.jpg]]// 77 +(% class="wikigeneratedid" id="HFigure2" %) 78 +((( 79 +[[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]] 80 +//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.// 42 42 ))) 43 43 ))) 83 +))) 84 +))) 85 +)))
- image1.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.MarkKohlmann - Size
-
... ... @@ -1,1 +1,0 @@ 1 -43.8 KB - Content
- image2.jpg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.MarkKohlmann - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.0 KB - Content
- 1640284131125-244.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +25.8 KB - Content
- wiki_zumlink to cresnet.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +759.1 KB - Content
- wiki_zumwired trans.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +208.8 KB - Content