... ... @@ -1,1 +1,1 @@ 1 -Zūm Wired 1 +*Zūm Wired - Content
-
... ... @@ -10,13 +10,13 @@ 10 10 11 11 Zūm Wired is a distributed lighting control system manufactured and distributed by Crestron that is set to replace the older Cresnet-based GLPP hardware. It uses industry standard 0-10V, phase dimming, DMX, and DALI protocols to allow for automated control of a building's lighting. 12 12 13 -A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same cables and connectorsasEthernet. The three networks in a Zūm Wired system thatadheretoEthernet standardsare:13 +A Zūm Wired system consists of several devices that are joined on three distinct networks that each use the same Ethernet wiring standards. The three networks in a Zūm Wired system that use Ethernet standard cabling are: 14 14 15 15 * Ethernet 16 16 * Zūm Net 17 17 * Zūm Link 18 18 19 - Additionally, traditional4-wireCresnetcanbethought ofas a subset ofZūmLink, anddetails on how to wireCresnetintoaZūm Link network canbefound[[below>>xwiki:WiringGuide.WiringOverview.ZūmNet.WebHome||anchor="HZ16BmLinktoCresnet"]].19 +In addition to the three networks listed above, there are two additional wiring standards that may be encountered to connect non-Zūm devices to the Zūm Link network, which are covered below under the Zūm Link section 20 20 21 21 == Ethernet == 22 22 ... ... @@ -26,16 +26,12 @@ 26 26 27 27 Zūm Net wiring should adhere to Ethernet cabling standards and use standard RJ-45 connectors. Zūm Net connects networked room-level controllers throughout the building to each other and to the lighting network. Each Zūm Net run will typically originate at a Hub or Processor panel and then connect to a number of ZUMNET-JBOX devices. 28 28 29 -Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable and devices are shown in purple on // [[Figure 1>>xwiki:Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HFigure1"]]//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices.29 +Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable and devices are shown in purple on //Figure 1//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices. ZUMNET-JBOX devices are covered in more detail [[here>>doc:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome]]. 30 30 31 -ZUMNET-JBOX devices are covered in more detail [[here>>doc:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome]]. 32 - 33 33 == Zūm Link == 34 34 35 -Zūm Link runs originate at a ZUMNET-JBOX and connect various Zūm Link devices within a a room to the ZUMNET-JBOX for that room. Zūm Link cable and JBOX devices are shown in orange on // [[Figure 1>>xwiki:Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HFigure1"]]//, while Zūm Link keypads are shown in green with orange outline. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the ZūmNet devices.Additionally, **do not loopZūmLink runs back to a ZūmNetdevice**;each Zūm LinkrunshouldoriginateatnorangeZūmLink porton a ZūmNet devicendend atthelast ZūmLink deviceon therun.33 +Zūm Link runs originate at a ZUMNET-JBOX and connect various Zūm Link devices within a a room to the ZUMNET-JBOX for that room. Zūm Link cable and JBOX devices are shown in orange on //Figure 1//, while Zūm Link keypads are shown in green with orange outline. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices. ZUMLINK-JBOX devices are covered in more detail [[here>>doc:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMLINK-JBOX).WebHome]]. 36 36 37 -Links to articles covering specific Zūm Link devices can be found [[here>>doc:Wiring Guide.Zūm Wired System Overview.WebHome]]. 38 - 39 39 === Zūm Link to Cresnet === 40 40 41 41 While most Zūm Link wiring will adhere to Ethernet cabling standards and utilize standard RJ-45 connectors, Zūm Link is not technically Ethernet. In some situations, it may be necessary to wire traditional Cresnet devices into a Zūm Link space. ... ... @@ -42,7 +42,7 @@ 42 42 43 43 In the future, Crestron will be producing a ZUMLINK-CNRJ45 adapter to allow for plug-and-play connections between Zūm Link RJ-45 connectors and 4-wire Cresnet devices. Until this product is available however, it is necessary to strip the Zūm Link wire and terminate it directly into a Cresnet phoenix connector or terminal block. 44 44 45 -The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the [[T568BStandard>>doc:WiringGuide.Wiring Overview.Ethernet.WebHome||anchor="HFigure 1"]] is as follows:41 +The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the T568B standard is as follows: 46 46 47 47 (% border="1" style="margin-right:auto" %) 48 48 |=(% style="width: 87px;" %)RJ-45 Pin|=(% style="width: 213px;" %)Function|=(% style="width: 257px;" %)Cresnet Color|=(% style="width: 426px;" %)T568-B Color ... ... @@ -50,27 +50,25 @@ 50 50 |(% style="width:87px" %)2|(% style="width:213px" %)24V|(% style="width:426px" %)Orange 51 51 |(% style="width:87px" %)3|(% style="width:213px" %)GND|(% colspan="1" rowspan="2" style="width:257px" %)Black|(% style="width:426px" %)White / Green 52 52 |(% style="width:87px" %)4|(% style="width:213px" %)GND|(% style="width:426px" %)Blue 53 -|(% style="width:87px" %)5|(% colspan="1" style="width:213px" %) (N/C)|(% colspan="1" style="width:257px" %)(N/C)|(% style="width:426px" %)White / Blue54 -|(% style="width:87px" %)6|(% colspan="1" style="width:213px" %)(N/C)|(% colspan="1" style="width:257px" %)(N/C)|(% style="width:426px" %)Green49 +|(% style="width:87px" %)5|(% colspan="1" rowspan="2" style="width:213px" %)N/C|(% colspan="1" rowspan="2" style="width:257px" %)N/C|(% style="width:426px" %)White / Blue 50 +|(% style="width:87px" %)6|(% style="width:426px" %)Green 55 55 |(% style="width:87px" %)7|(% style="width:213px" %)Cresnet Y (Data +)|(% style="width:257px" %)White|(% style="width:426px" %)White / Brown 56 56 |(% style="width:87px" %)8|(% style="width:213px" %)Cresnet Z (Data -)|(% style="width:257px" %)Blue|(% style="width:426px" %)Brown 57 57 58 -//[[Figure 2>>xwiki:Wiring Guide.Wiring Overview.Zūm Net.WebHome||anchor="HFigure2"]]// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:Wiring Guide.Wiring Overview.Cresnet.WebHome]]. 54 +//Figure 2// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:Wiring Guide.Wiring Overview.Cresnet.WebHome]]. 55 + 56 +=== Non-System Sensor Integration === 57 + 58 +L 59 59 ))) 60 60 61 61 62 62 (% class="col-xs-12 col-sm-4" %) 63 63 ((( 64 -(% class="wikigeneratedid" id="HFigure1" %) 65 -((( 66 66 [[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]] 67 67 //Figure 1: Overview of a typical Zūm Wired space [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.1]]// 68 -))) 69 69 70 -(% class="wikigeneratedid" id="HFigure2" %) 71 -((( 72 72 [[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]] 73 73 //Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - white/blue and green wire left bare for illustration purposes only; during actual installation they should be capped and insulated.// 74 74 ))) 75 75 ))) 76 -)))
- 1640284131125-244.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,1 +1,0 @@ 1 -25.8 KB - Content