Changes for page Zūm Wired Wiring Overview
Last modified by Alexander Mott on 2024/03/01 18:46
From version 23.1
edited by Alexander Mott
on 2021/12/22 22:30
on 2021/12/22 22:30
Change comment:
There is no comment for this version
To version 24.1
edited by Alexander Mott
on 2021/12/22 22:33
on 2021/12/22 22:33
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -20,7 +20,7 @@ 20 20 21 21 == Ethernet == 22 22 23 -Ethernet provides the backbone of the lighting network. Ethernet joins the Hub panels to each other, the processor, and (if the design calls for it) the building LAN. All Ethernet cabling should adhere to the [[Ethernet standards>>doc:Wiring Guide.Wiring Overview.Ethernet.WebHome]] as coveredelsewhereon thiswiki.23 +Ethernet provides the backbone of the lighting network. Ethernet joins the Hub panels to each other, the processor, and (if the design calls for it) the building LAN. All Ethernet cabling should adhere to the [[Ethernet standards>>doc:Wiring Guide.Wiring Overview.Ethernet.WebHome]] for Crestron systems. 24 24 25 25 == Zūm Net == 26 26 ... ... @@ -41,15 +41,15 @@ 41 41 The pin-out to connect a Cresnet device to a Zūm Link network that has been terminated per the T568B standard is as follows: 42 42 43 43 (% border="1" style="margin-right:auto" %) 44 -|(% style="width: 130px" %)RJ-45 Pin|(% style="width:271px" %)Function|(% style="width:194px" %)Cresnet Color|(% style="width:426px" %)T568-B Color45 -|(% style="width: 130px" %)1|(% style="width:271px" %)24V|(% colspan="1" rowspan="2" style="width:194px" %)Red|(% style="width:426px" %)White / Orange46 -|(% style="width: 130px" %)2|(% style="width:271px" %)24V|(% style="width:426px" %)Orange47 -|(% style="width: 130px" %)3|(% style="width:271px" %)GND|(% colspan="1" rowspan="2" style="width:194px" %)Black|(% style="width:426px" %)White / Green48 -|(% style="width: 130px" %)4|(% style="width:271px" %)GND|(% style="width:426px" %)Blue49 -|(% style="width: 130px" %)5|(% colspan="1" rowspan="2" style="width:271px" %)N/C|(% colspan="1" rowspan="2" style="width:194px" %)N/C|(% style="width:426px" %)White / Blue50 -|(% style="width: 130px" %)6|(% style="width:426px" %)Green51 -|(% style="width: 130px" %)7|(% style="width:271px" %)Data + (Cresnet Y)|(% style="width:194px" %)White|(% style="width:426px" %)White / Brown52 -|(% style="width: 130px" %)8|(% style="width:271px" %)Data - (Cresnet Z)|(% style="width:194px" %)Blue|(% style="width:426px" %)Brown44 +|=(% style="width: 87px;" %)RJ-45 Pin|=(% style="width: 213px;" %)Function|=(% style="width: 257px;" %)Cresnet Color|=(% style="width: 426px;" %)T568-B Color 45 +|(% style="width:87px" %)1|(% style="width:213px" %)24V|(% colspan="1" rowspan="2" style="width:257px" %)Red|(% style="width:426px" %)White / Orange 46 +|(% style="width:87px" %)2|(% style="width:213px" %)24V|(% style="width:426px" %)Orange 47 +|(% style="width:87px" %)3|(% style="width:213px" %)GND|(% colspan="1" rowspan="2" style="width:257px" %)Black|(% style="width:426px" %)White / Green 48 +|(% style="width:87px" %)4|(% style="width:213px" %)GND|(% style="width:426px" %)Blue 49 +|(% style="width:87px" %)5|(% colspan="1" rowspan="2" style="width:213px" %)N/C|(% colspan="1" rowspan="2" style="width:257px" %)N/C|(% style="width:426px" %)White / Blue 50 +|(% style="width:87px" %)6|(% style="width:426px" %)Green 51 +|(% style="width:87px" %)7|(% style="width:213px" %)Cresnet Y (Data +)|(% style="width:257px" %)White|(% style="width:426px" %)White / Brown 52 +|(% style="width:87px" %)8|(% style="width:213px" %)Cresnet Z (Data -)|(% style="width:257px" %)Blue|(% style="width:426px" %)Brown 53 53 54 54 //Figure 2// illustrates how a Zūm Link cable should be terminated at a Cresnet phoenix connector (recall that the standard left-to-right color code for Cresnet wiring is red-white-blue-black). Cresnet wiring is covered in more detail [[here>>doc:Wiring Guide.Wiring Overview.Cresnet.WebHome]]. 55 55