Last modified by Alexander Mott on 2024/03/01 18:46

From version 12.1
edited by Alexander Mott
on 2021/12/21 23:52
Change comment: There is no comment for this version
To version 19.1
edited by Alexander Mott
on 2021/12/22 22:14
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,7 +14,7 @@
14 14  
15 15  * Ethernet
16 16  * Zūm Net
17 -* Zūm Link - each Zūm Link run originates at a ZUMNET-JBOX and connects various Zūm Link devices within a a room. Zūm Link cable and JBOX devices are shown in orange on //Figure 1//, while Zūm Link keypads are shown in green.
17 +* Zūm Link
18 18  
19 19  In addition to the three networks listed above, there are two additional wiring standards that may be encountered to connect non-Zūm devices to the Zūm Link network, which are covered below under the Zūm Link section
20 20  
... ... @@ -24,16 +24,20 @@
24 24  
25 25  == Zūm Net ==
26 26  
27 -Zūm Net connects networked room-level controllers throughout the space to each other and to the lighting network. Each Zūm Net run will typically originate at a Hub or Processor panel and then connect to a number of ZUMNET-JBOX devices. There should be one ZUMNET-JBOX per room. Zūm Net cable and devices are shown in purple on //Figure 1//
27 +Zūm Net wiring should adhere to Ethernet cabling standards and use standard RJ-45 connectors. Zūm Net connects networked room-level controllers throughout the building to each other and to the lighting network. Each Zūm Net run will typically originate at a Hub or Processor panel and then connect to a number of ZUMNET-JBOX devices.
28 28  
29 +Typically, there is only one ZUMNET-JBOX per room. Zūm Net cable and devices are shown in purple on //Figure 1//. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices. ZUMNET-JBOX devices are covered in more detail [[here>>doc:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMNET-JBOX).WebHome]].
30 +
29 29  == Zūm Link ==
30 30  
31 -Lo
33 +Zūm Link runs originate at a ZUMNET-JBOX and connect various Zūm Link devices within a a room to the ZUMNET-JBOX for that room. Zūm Link cable and JBOX devices are shown in orange on //Figure 1//, while Zūm Link keypads are shown in green with orange outline. **It is very important to never connect a Zūm Link cable to a Zūm Net port** as this may damage the Zūm net devices. ZUMLINK-JBOX devices are covered in more detail [[here>>doc:Wiring Guide.Zūm Wired System Overview.Load Controllers (ZUMLINK-JBOX).WebHome]].
32 32  
33 33  === Zūm Link to Cresnet ===
34 34  
35 -L
37 +While most Zūm Link wiring will adhere to Ethernet cabling standards and utilize standard RJ-45 connectors, Zūm Link is not technically Ethernet. In some situations, it may be necessary to wire traditional Cresnet devices into a Zūm Link space.
36 36  
39 +In the future, Crestron will be releasing a ZUMLINK-CNRJ45 adapter to make connections between the Cat 5e+ Zūm Link wire and traditional Cresnet easier,
40 +
37 37  === Non-System Sensor Integration ===
38 38  
39 39  L
... ... @@ -42,10 +42,10 @@
42 42  
43 43  (% class="col-xs-12 col-sm-4" %)
44 44  (((
45 -[[image:wiki_zumwired trans.png]]
49 +[[[[image:wiki_zumwired trans.png]]>>attach:wiki_zumwired trans.png]]
46 46  //Figure 1: Overview of a typical Zūm Wired space [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumwired%20trans.png?rev=1.1]]//
47 47  
48 -[[image:Templates.Article.Template.WebHome@image2.jpg]]
49 -//Figure 2: [[Waves>>https://commons.wikimedia.org/wiki/File:Culebra_-_Playa_de_Flamenco.jpg]]//
52 +[[[[image:wiki_zumlink to cresnet.png||alt="image2.jpg"]]>>attach:wiki_zumlink to cresnet.png]]
53 +//Figure 2: Zūm Link to Cresnet Wiring [[(larger)>>https://wiki.chiefintegrations.com/download/Wiring%20Guide/Wiring%20Overview/Z%C5%ABm%20Net/WebHome/wiki_zumlink%20to%20cresnet.png?rev=1.1]] - note that white/blue and green wire are bare for illustration purposes; in actual installation they should be capped and insulated//
50 50  )))
51 51  )))
1640211037270-466.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +1.3 MB
Content
wiki_zumlink to cresnet.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,0 +1,1 @@
1 +759.1 KB
Content