Changes for page Phase Dimming Troubleshooting
Last modified by Alexander Mott on 2024/01/05 18:55
From version 16.1
edited by Alexander Mott
on 2022/04/20 17:12
on 2022/04/20 17:12
Change comment:
There is no comment for this version
To version 17.1
edited by Alexander Mott
on 2022/04/26 15:42
on 2022/04/26 15:42
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -92,15 +92,19 @@ 92 92 93 93 Below is a table of actual phase dimming readings at various percentage brightness for some Crestron lighting controllers. Measurements were taken from 120V modules using a true-RMS meter (note that the oscilloscope graph appears high because it is reading the peak voltage). 94 94 95 -|=(% style="width: 99px;" %)Percentage Brightness|=(% style="width: 764px;" %)CLX-2DIMU8 Oscilloscope Output|=(% style="width: 119px;" %)CLX-2DIMU8 Reading (V AC)|=(% style="width: 119px;" %)GL-EXP-DIMU-CN Reading (Reverse Phase) 96 -|(% style="width:99px" %)100%|(% style="width:764px" %)[[image:1649956710772-275.png]]|(% style="width:119px" %)~~118|(% style="width:119px" %)120.4 V AC 97 -|(% style="width:99px" %)80%|(% style="width:764px" %)[[image:1649956722651-285.png]]|(% style="width:119px" %)~~112|(% style="width:119px" %)113.8 V AC 98 -|(% style="width:99px" %)60%|(% style="width:764px" %)[[image:1649956734539-236.png]]|(% style="width:119px" %)~~97|(% style="width:119px" %)99.1 V AC 99 -|(% style="width:99px" %)50%|(% style="width:764px" %)[[image:1649956742753-637.png]]|(% style="width:119px" %) |(% style="width:119px" %)90.5 V AC 100 -|(% style="width:99px" %)40%|(% style="width:764px" %)[[image:1649956753212-813.png]]|(% style="width:119px" %)~~74|(% style="width:119px" %)78.1 V AC 101 -|(% style="width:99px" %)20%|(% style="width:764px" %)[[image:1649956765039-459.png]]|(% style="width:119px" %)~~47|(% style="width:119px" %)52.72 V AC 102 -|(% style="width:99px" %)0%|(% style="width:764px" %)[[image:1649956845393-707.png]]|(% style="width:119px" %)~~0.005|(% style="width:119px" %)1.209 V AC 95 +|=(% style="width: 99px;" %)Percentage Brightness|=(% style="width: 764px;" %)CLX-2DIMU8 Oscilloscope Output|=(% style="width: 119px;" %)CLX-2DIMU8 Reading (Reverse Phase)|=(% style="width: 119px;" %)CLX-2DIMU8 Reading (Forward Phase)|=(% style="width: 119px;" %)GL-EXP-DIMU-CN Reading (Reverse Phase) 96 +|(% style="width:99px" %)100%|(% style="width:764px" %)[[image:1649956710772-275.png]]|(% style="width:119px" %)((( 97 +output1 103 103 99 +~~118 100 +)))|(% style="width:119px" %)output2|(% style="width:119px" %)120.4 V AC 101 +|(% style="width:99px" %)80%|(% style="width:764px" %)[[image:1649956722651-285.png]]|(% style="width:119px" %)~~112|(% style="width:119px" %) |(% style="width:119px" %)113.8 V AC 102 +|(% style="width:99px" %)60%|(% style="width:764px" %)[[image:1649956734539-236.png]]|(% style="width:119px" %)~~97|(% style="width:119px" %) |(% style="width:119px" %)99.1 V AC 103 +|(% style="width:99px" %)50%|(% style="width:764px" %)[[image:1649956742753-637.png]]|(% style="width:119px" %) |(% style="width:119px" %) |(% style="width:119px" %)90.5 V AC 104 +|(% style="width:99px" %)40%|(% style="width:764px" %)[[image:1649956753212-813.png]]|(% style="width:119px" %)~~74|(% style="width:119px" %) |(% style="width:119px" %)78.1 V AC 105 +|(% style="width:99px" %)20%|(% style="width:764px" %)[[image:1649956765039-459.png]]|(% style="width:119px" %)~~47|(% style="width:119px" %) |(% style="width:119px" %)52.72 V AC 106 +|(% style="width:99px" %)0%|(% style="width:764px" %)[[image:1649956845393-707.png]]|(% style="width:119px" %)~~0.005|(% style="width:119px" %) |(% style="width:119px" %)1.209 V AC 107 + 104 104 105 105 ))) 106 106