Changes for page Ethernet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 18:55
From version 3.4
edited by Alexander Mott
on 2021/12/20 23:36
on 2021/12/20 23:36
Change comment:
There is no comment for this version
To version 3.3
edited by Alexander Mott
on 2021/12/20 23:25
on 2021/12/20 23:25
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Ethernet 1 +*Ethernet - Content
-
... ... @@ -8,27 +8,19 @@ 8 8 ((( 9 9 = Ethernet Wiring = 10 10 11 -Ethernet is used for various devices within a Crestron Lighting Control system, including connecting a lighting control processor to the lighting network, connecting Zūm Net devices to the lighting network, connecting TSW touch-screen interfaces to the lighting network, a nd connecting thelighting networkitself to a building network (building LAN).11 +Ethernet wiring is used for various devices within a Crestron Lighting Control system, including connecting a lighting control processor to the lighting network, connecting Zūm Net devices to the lighting network, and connecting TSW touch-screen interfaces to the lighting network, among other devices. 12 12 13 13 == Cabling == 14 14 15 -All cable should be Category 5e orgreater(includingCategory 6andCategory 6a).15 +All cable should be at least Category 5e, if not Category 6 or Category 6a. The 16 16 17 -The maximum length of any single ethernet run is 100 meters (328 feet). Runs longer than this will require a powered ethernet switch (such as a CEN-SW-POE-5) to be installed midway through the run to enable proper communication. 18 - 19 19 == Terminations == 20 20 21 21 Cresnet Ethernet devices require the use of RJ-45 connectors. 22 22 23 -While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is **recommended to use the T568B pin-out for all terminations.** By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.21 +While either T568A or T568B termination pin-out are acceptable, it is **recommended to use the T568B pin-out for all terminations.** By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard. 24 24 25 25 See// Figure 1 //for the T568-B pin-out. 26 - 27 -When making RJ-45 terminations, take care that the wires are in the correct order and pushed all the way to the end of the connector. A crimping tool with sharp blades that have not been dulled with use also helps in making good terminations. 28 - 29 -== Testing == 30 - 31 - 32 32 ))) 33 33 34 34