Changes for page Ethernet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 18:55
From version 29.2
edited by Alexander Mott
on 2024/01/05 18:47
on 2024/01/05 18:47
Change comment:
Update document after refactoring.
To version 7.1
edited by Alexander Mott
on 2021/12/22 21:32
on 2021/12/22 21:32
Change comment:
Deleted image "image1.jpg"
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -Ethernet Wiring Overview1 +Ethernet - Parent
-
... ... @@ -1,1 +1,1 @@ 1 - SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.WebHome1 +Wiring Guide.Wiring Overview.WebHome - Content
-
... ... @@ -1,48 +1,40 @@ 1 +{{box title="**Contents**"}} 2 +{{toc/}} 3 +{{/box}} 4 + 1 1 (% class="row" %) 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -(% class="box errormessage" %) 6 -((( 7 -All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues. 8 -))) 9 += Ethernet Wiring = 9 9 10 -Ethernet is used toconnectvarious devices within a Crestron Lighting Control systemto thelightingnetwork as well asconnectingthelighting networkitselftoabuilding network(buildingLAN).The term"lighting network"refers to the infrastructurethatconnects Ethernet-capableCrestrondevicesand allowsforcommunicationbetweenthem.11 +Ethernet is used for various devices within a Crestron Lighting Control system, including connecting a lighting control processor to the lighting network, connecting Zūm Net devices to the lighting network, connecting TSW touch-screen interfaces to the lighting network, and connecting the lighting network itself to a building network (building LAN). 11 11 12 - Thelighting network will typically consist ofCrestron panels with at least one Ethernet device and at least one Ethernet switch. The device(s) within a panel are connected to the Ethernet switch from the factory,but cablingmust be provided to connect the Ethernet switches within separate panels to each other and to the building LAN (if such a connection is shown on the submittals). Additionally, some devices in the field (such as GLPAC lighting controllers or TSW touch screens) must be connected to the lighting network by running an Ethernet cable from their location in the field back to an Ethernet switch in one of the lighting panels.13 +== Cabling == 13 13 14 -= Cabling = 15 - 16 16 All cable should be Category 5e or greater (including Category 6 and Category 6a). 17 17 18 18 The maximum length of any single ethernet run is 100 meters (328 feet). Runs longer than this will require a powered ethernet switch (such as a CEN-SW-POE-5) to be installed midway through the run to enable proper communication. 19 19 20 -= Terminations = 19 +== Terminations == 21 21 22 -Cresnet Ethernet devices require the use of RJ-45 connectors. **DO NOT use "EZ" or passthrough-style RJ-45 connectors.** All RJ-45 connectors must be standard, closed-end type connectors to ensure correct functionality of the system.21 +Cresnet Ethernet devices require the use of RJ-45 connectors. 23 23 24 -While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is recommended to use the T568B pin-out for all terminations. By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard. 23 +While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is **recommended to use the T568B pin-out for all terminations.** By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard. 25 25 26 -See [[Figure 1>>doc:SHOWRUNNER™Setup Guide.Wiring Guide.Wiring Overview.Ethernet.WebHome||anchor="HFigure1"]]//25 +See// Figure 1 //for the T568-B pin-out. 27 27 28 28 When making RJ-45 terminations, take care that the wires are in the correct order and pushed all the way to the end of the connector. A crimping tool with sharp blades that have not been dulled with use also helps in making good terminations. 29 29 30 -= Testing and Troubleshooting = 29 +== Testing and Troubleshooting == 31 31 32 -Issues with Ethernet cabling typically will not be discovered until a lighting technician is on-site to commission the Crestron system.Commonly available cableverification testers(such as the Klein Scout)areuseful inbutthe only way to definitively rule out Ethernet cable issues iswiththeuseofacable Qualification or Certificationtester.31 +Issues with Ethernet cabling typically will not be noticed until a lighting technician is on-site to commission the Crestron system. While commonly available cable testers such as the Klein Scout can help in determining basic faults such as crossed, shorted, or broken wires, the only way to definitively rule out Ethernet cable issues is to use a Cable Qualification Tester or Cable Certification Tester. 33 33 ))) 34 34 35 35 36 36 (% class="col-xs-12 col-sm-4" %) 37 37 ((( 38 -{{box title="**CONTENTS**"}} 39 -{{toc/}} 40 -{{/box}} 41 - 42 -(% class="wikigeneratedid" id="HFigure1" %) 43 -((( 44 -[[[[image:T568B pin-out.png||alt="image1.jpg"]]>>attach:T568B pin-out.png]] 37 +[[image:T568B pin-out.png||alt="image1.jpg"]] 45 45 //Figure 1: ANSI/TIA-568-B.2001 T568B Pin-Out// 46 46 ))) 47 47 ))) 48 -)))
- image2.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.MarkKohlmann - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.0 KB - Content