Changes for page Ethernet Wiring Overview

Last modified by Alexander Mott on 2024/01/05 18:55

From version 27.1
edited by Alexander Mott
on 2023/10/13 16:13
Change comment: There is no comment for this version
To version 24.1
edited by Alexander Mott
on 2022/09/17 00:42
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,11 +1,12 @@
1 +{{box title="**CONTENTS**"}}
2 +{{toc/}}
3 +{{/box}}
4 +
1 1  (% class="row" %)
2 2  (((
3 3  (% class="col-xs-12 col-sm-8" %)
4 4  (((
5 -(% class="box errormessage" %)
6 -(((
7 -All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues.
8 -)))
9 += Overview =
9 9  
10 10  Ethernet is used to connect various devices within a Crestron Lighting Control system to the lighting network as well as connecting the lighting network itself to a building network (building LAN). The term "lighting network" refers to the infrastructure that connects Ethernet-capable Crestron devices and allows for communication between them.
11 11  
... ... @@ -19,9 +19,9 @@
19 19  
20 20  = Terminations =
21 21  
22 -Cresnet Ethernet devices require the use of RJ-45 connectors. **DO NOT use "EZ" or passthrough-style RJ-45 connectors.** All RJ-45 connectors must be standard, closed-end type connectors to ensure correct functionality of the system.
23 +Cresnet Ethernet devices require the use of RJ-45 connectors.
23 23  
24 -While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is recommended to use the T568B pin-out for all terminations. By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.
25 +While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is **recommended to use the T568B pin-out for all terminations.** By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.
25 25  
26 26  See //[[Figure 1>>doc:WebHome||anchor="HFigure1"]]// for the T568-B pin-out.
27 27  
... ... @@ -35,10 +35,7 @@
35 35  
36 36  (% class="col-xs-12 col-sm-4" %)
37 37  (((
38 -{{box title="**CONTENTS**"}}
39 -{{toc/}}
40 -{{/box}}
41 -
39 +(((
42 42  (% class="wikigeneratedid" id="HFigure1" %)
43 43  (((
44 44  [[[[image:T568B pin-out.png||alt="image1.jpg"]]>>attach:T568B pin-out.png]]
... ... @@ -46,3 +46,4 @@
46 46  )))
47 47  )))
48 48  )))
47 +)))