... ... @@ -1,1 +1,1 @@
1 -Ethernet
1 +Ethernet Wiring Overview
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Setup Guide.Wiring Guide.Wiring Overview.WebHome
1 +SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.WebHome
Content
... ... @@ -2,7 +2,10 @@
2 2  (((
3 3  (% class="col-xs-12 col-sm-8" %)
4 4  (((
5 -= Overview =
5 +(% class="box errormessage" %)
6 +(((
7 +All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues.
8 +)))
6 6  
7 7  Ethernet is used to connect various devices within a Crestron Lighting Control system to the lighting network as well as connecting the lighting network itself to a building network (building LAN). The term "lighting network" refers to the infrastructure that connects Ethernet-capable Crestron devices and allows for communication between them.
8 8  
... ... @@ -16,11 +16,11 @@
16 16  
17 17  = Terminations =
18 18  
19 -Cresnet Ethernet devices require the use of RJ-45 connectors.
22 +Cresnet Ethernet devices require the use of RJ-45 connectors. **DO NOT use "EZ" or passthrough-style RJ-45 connectors.** All RJ-45 connectors must be standard, closed-end type connectors to ensure correct functionality of the system.
20 20  
21 -While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is **recommended to use the T568B pin-out for all terminations.** By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.
24 +While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is recommended to use the T568B pin-out for all terminations. By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.