... ... @@ -1,12 +5,11 @@
1 -{{box title="**CONTENTS**"}}
2 -{{toc/}}
3 -{{/box}}
4 -
5 5  (% class="row" %)
6 6  (((
7 7  (% class="col-xs-12 col-sm-8" %)
8 8  (((
9 -= Overview =
5 +(% class="box errormessage" %)
6 +(((
7 +All Category 5e/6a cabling must be terminated with standard, closed-end RJ-45 connectors. Cables terminated with "EZ" or passthrough connectors are known to cause networking and communications issues.
8 +)))
10 10  
11 11  Ethernet is used to connect various devices within a Crestron Lighting Control system to the lighting network as well as connecting the lighting network itself to a building network (building LAN). The term "lighting network" refers to the infrastructure that connects Ethernet-capable Crestron devices and allows for communication between them.
12 12  
... ... @@ -20,9 +20,9 @@
20 20  
21 21  = Terminations =
22 22  
23 -Cresnet Ethernet devices require the use of RJ-45 connectors.
22 +Cresnet Ethernet devices require the use of RJ-45 connectors. **DO NOT use "EZ" or passthrough-style RJ-45 connectors.** All RJ-45 connectors must be standard, closed-end type connectors to ensure correct functionality of the system.
24 24  
25 -While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is **recommended to use the T568B pin-out for all terminations.** By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.
24 +While either T568A or T568B termination pin-out are acceptable as long as they are used consistently, it is recommended to use the T568B pin-out for all terminations. By keeping to one standard, it is easier to stay consistent and prevent errors where the two sides of a single cable are not terminated to the same standard.
26 26  
27 27  See //[[Figure 1>>doc:WebHome||anchor="HFigure1"]]// for the T568-B pin-out.
28 28  
... ... @@ -36,7 +36,10 @@
36 36  
37 37  (% class="col-xs-12 col-sm-4" %)
38 38  (((
39 -(((
38 +{{box title="**CONTENTS**"}}
39 +{{toc/}}
40 +{{/box}}
41 +
40 40  (% class="wikigeneratedid" id="HFigure1" %)
41 41  (((
42 42  [[[[image:T568B pin-out.png||alt="image1.jpg"]]>>attach:T568B pin-out.png]]
... ... @@ -44,4 +44,3 @@
44 44  )))
45 45  )))
46 46  )))
47 -)))