Changes for page Cresnet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 23:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -4,8 +4,17 @@ 4 4 ((( 5 5 Communications between Crestron Cresnet devices occurs on the Cresnet bus. Cresnet is Crestron's proprietary 4-wire communications network that provides both 24V DC power and low-voltage, bidirectional communication that adheres to to RS-485 standards. 6 6 7 -Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Therearewolimiting factors as to the numberofCresnetdevices thatcanbe supportedonasingle Cresnetbus:the numberof availableCresnetaddressesandtheamountof availablepower.7 +Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host: 8 8 9 +| | | | | 10 +| | | | | 11 +| | | | | 12 +| | | | | 13 +| | | | | 14 + 15 +Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device. 16 + 17 + 9 9 Zūm Link wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]. 10 10 11 11 = Cabling = ... ... @@ -12,27 +12,20 @@ 12 12 13 13 Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices and consists of a 4-wire, 2-pair cable available directly from Crestron with either plenum and non-plenum rated jackets. 14 14 15 -|=Pair|=Color|=Purpose|=Pinout 16 -|(% colspan="1" rowspan="2" %)18 AWG pair|Red|24 V DC Power|24 17 -|Black|Common|G 18 -|(% colspan="1" rowspan="2" %)22 AWG shielded twisted pair|White|Data +|Y 19 -|Blue|Data -|Z 24 +(% class="table-condensed" %) 25 +|=(% style="width: 307px;" %)Pair|=(% style="width: 287px;" %)Color|=(% style="width: 380px;" %)Purpose 26 +|(% colspan="1" rowspan="2" style="width:307px" %)18 AWG pair|(% style="width:287px" %)Red|(% style="width:380px" %)24 V DC Power 27 +|(% style="width:287px" %)Black|(% style="width:380px" %)Common 28 +|(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data + 29 +|(% style="width:287px" %)Blue|(% style="width:380px" %)Data - 20 20 21 21 = Terminations = 22 22 23 23 Lorem ipsum dolor sit amet, 24 24 25 -== At Devices == 26 - 27 -consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. 28 - 29 29 See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 30 30 See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 31 31 32 -== At Panels == 33 - 34 -Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum dolore eu fugiat nulla pariatur. Excepteur sint occaecat cupidatat non proident, sunt in culpa qui officia deserunt mollit anim id est laborum. 35 - 36 36 = Crestron Wiring Notes = 37 37 38 38 Crestron includes some general Cresnet wiring guidelines in their submittals. Many of these suggestions are covered above, but we have included them here for reference: