Changes for page Cresnet Wiring Overview

Last modified by Alexander Mott on 2024/01/05 23:42

From version 20.3
edited by Alexander Mott
on 2024/01/05 20:32
Change comment: (Autosaved)
To version 20.6
edited by Alexander Mott
on 2024/01/05 20:47
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -4,12 +4,20 @@
4 4  (((
5 5  Communications between Crestron Cresnet devices occurs on the Cresnet bus. Cresnet is Crestron's proprietary 4-wire communications network that provides both 24V DC power and low-voltage, bidirectional communication that adheres to to RS-485 standards.
6 6  
7 -Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has only one //host//r //master// device and one or more //client// or //slave// devices
7 +Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//).
8 8  
9 +Zūm Link wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]].
10 +
9 9  = Cabling =
10 10  
11 -Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices. Cresnet
13 +Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices and consists of a 4-wire, 2-pair cable available directly from Crestron with either plenum and non-plenum rated jackets.
12 12  
15 +|=Pair|=Color|=Purpose|=Pinout
16 +|(% colspan="1" rowspan="2" %)18 AWG pair|Red|24 V DC Power|24
17 +|Black|Common|G
18 +|(% colspan="1" rowspan="2" %)22 AWG shielded twisted pair|White|Data +|Y
19 +|Blue|Data -|Z
20 +
13 13  = Terminations =
14 14  
15 15  Lorem ipsum dolor sit amet,