... ... @@ -6,17 +6,18 @@
6 6  
7 7  Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host:
8 8  
9 -|=(% style="width: 186px;" %)Host|=(% style="width: 62px;" %)Available Addresses|=Start|=End|=Notes
10 -|(% style="width:186px" %)3-Series or
11 -4-Series processors|(% style="width:62px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks
12 -|(% style="width:186px" %)(((
9 +(% class="table-condensed" %)
10 +|=(% style="width: 171px;" %)Host|=(% style="width: 96px;" %)Available Addresses|=Start|=End|=Notes
11 +|(% style="width:171px" %)3-Series or
12 +4-Series processors|(% style="width:96px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks
13 +|(% style="width:171px" %)(((
13 13  DIN-CENCN-2 or
14 14  DIN-CENCN-2-POE
15 -)))|(% style="width:62px" %)(((
16 +)))|(% style="width:96px" %)(((
16 16  25 per Net (50 total)
17 17  )))|03|1B|
18 -|(% style="width:186px" %)ZUMNET-JBOX-16A-LV or
19 -ZUMNET-JBOX-DALI|(% style="width:62px" %)32|03|22|(((
19 +|(% style="width:171px" %)ZUMNET-JBOX-16A-LV
20 +or ZUMNET-JBOX-DALI|(% style="width:96px" %)32|03|22|(((
20 20  ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected
21 21  
22 22  Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]
... ... @@ -35,7 +35,8 @@
35 35  |(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data +
36 36  |(% style="width:287px" %)Blue|(% style="width:380px" %)Data -
37 37  
38 -= Terminations =
39 +(% class="wikigeneratedid" %)
40 +Terminations
39 39  
40 40  Lorem ipsum dolor sit amet,