Details
- Page properties
-
- Content
-
... ... @@ -2,27 +2,48 @@ 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) 4 4 ((( 5 -Communications between Crestron Cresnet devices occurs on the Cresnet bus. TheCresnetbusis Crestron's proprietary 4-wire communications network that provides both 24V DC power and bidirectional communication5 +Communications between Crestron Cresnet devices occurs on the Cresnet bus. Cresnet is Crestron's proprietary 4-wire communications network that provides both 24V DC power and low-voltage, bidirectional communication that adheres to to RS-485 standards. 6 6 7 - =Cabling=7 +Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host: 8 8 9 -Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices. Cresnet 9 +(% class="table-condensed" %) 10 +|=(% style="width: 171px;" %)Host|=(% style="width: 96px;" %)Available Addresses|=Start|=End|=Notes 11 +|(% style="width:171px" %)3-Series or 12 +4-Series processors|(% style="width:96px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks 13 +|(% style="width:171px" %)((( 14 +DIN-CENCN-2 or 15 +DIN-CENCN-2-POE 16 +)))|(% style="width:96px" %)((( 17 +25 per Net (50 total) 18 +)))|03|1B| 19 +|(% style="width:171px" %)ZUMNET-JBOX-16A-LV 20 +or ZUMNET-JBOX-DALI|(% style="width:96px" %)32|03|22|((( 21 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected 10 10 11 -= Terminations = 23 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] 24 +))) 12 12 13 - Lorem ipsumdolor sit amet,26 +Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device. 14 14 15 -= =At Devices==28 += Cabling = 16 16 17 -c onsecteturadipiscingelit,seddoeiusmod tempor incididuntutlabore etdoloregnaaliqua.30 +Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices and consists of a 4-wire, 2-pair cable available directly from Crestron with either plenum and non-plenum rated jackets. 18 18 19 -See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 20 -See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 32 +(% class="table-condensed" %) 33 +|=(% style="width: 307px;" %)Pair|=(% style="width: 287px;" %)Color|=(% style="width: 380px;" %)Purpose 34 +|(% colspan="1" rowspan="2" style="width:307px" %)18 AWG pair|(% style="width:287px" %)Red|(% style="width:380px" %)24 V DC Power 35 +|(% style="width:287px" %)Black|(% style="width:380px" %)Common 36 +|(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data + 37 +|(% style="width:287px" %)Blue|(% style="width:380px" %)Data - 21 21 22 -== At Panels == 39 +(% class="wikigeneratedid" %) 40 +Terminations 23 23 24 - Ut enim ad minim veniam, quis nostrudexercitation ullamcolaboris nisi ut aliquipex ea commodo consequat. Duis aute irure dolor in reprehenderit in voluptate velit esse cillum doloreeu fugiat nulla pariatur. Excepteursintoccaecat cupidatat non proident, sunt in culpa qui officia deseruntmollit anim idestlaborum.42 +Lorem ipsum dolor sit amet, 25 25 44 +See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 45 +See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 46 + 26 26 = Crestron Wiring Notes = 27 27 28 28 Crestron includes some general Cresnet wiring guidelines in their submittals. Many of these suggestions are covered above, but we have included them here for reference: