Changes for page Cresnet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 23:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,17 +6,22 @@ 6 6 7 7 Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host: 8 8 9 -|=(% style="width: 186px;" %)Host|=(% style="width: 62px;" %)Available Addresses|=Start|=End|=Notes 10 -|(% style="width:186px" %)3-Series or 4-Series processor |(% style="width:62px" %)252^^1^^|03|FE|^^1^^Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger networks 11 -|(% style="width:186px" %)DIN-CENCN-2(-POE)|(% style="width:62px" %)((( 9 +(% class="table-condensed" %) 10 +|=(% style="width: 171px;" %)Host|=(% style="width: 96px;" %)Available Addresses|=Start|=End|=Notes 11 +|(% style="width:171px" %)3-Series or 12 +4-Series processors|(% style="width:96px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks 13 +|(% style="width:171px" %)((( 14 +DIN-CENCN-2 or 15 +DIN-CENCN-2-POE 16 +)))|(% style="width:96px" %)((( 12 12 25 per Net (50 total) 13 13 )))|03|1B| 14 -|(% style="width:186px" %)ZUMNET-JBOX-*|(% style="width:62px" %)32^^1^^|03|22|((( 15 -Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] 19 +|(% style="width:171px" %)ZUMNET-JBOX-16A-LV 20 +or ZUMNET-JBOX-DALI|(% style="width:96px" %)32|03|22|((( 21 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected 16 16 17 - ^^1^^ZUMNET-JBOXlocalcontrollercountsas adevice;only31 additionalZūmLink orCresnetdevices may beconnected23 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] 18 18 ))) 19 -|(% style="width:186px" %)GLPAC-DIMFLV*|(% style="width:62px" %) |03| | 20 20 21 21 Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device. 22 22 ... ... @@ -31,7 +31,8 @@ 31 31 |(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data + 32 32 |(% style="width:287px" %)Blue|(% style="width:380px" %)Data - 33 33 34 -= Terminations = 39 +(% class="wikigeneratedid" %) 40 +Terminations 35 35 36 36 Lorem ipsum dolor sit amet, 37 37