Changes for page Cresnet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 23:42
To version 21.1
edited by Alexander Mott
on 2024/01/05 22:34
on 2024/01/05 22:34
Change comment:
Uploaded new attachment "1704494079517-977.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,15 +6,22 @@ 6 6 7 7 Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host: 8 8 9 -|=Host|=Available Addresses|=Start|=End|=Notes 10 -|3-Series or 4-Series processor | |03|FE| 11 -|DIN-CENCN-2(-POE)| |03| | 12 -|ZUMNET-JBOX-*|32^^1^^|03|22|((( 13 -Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]. 9 +(% class="table-condensed" %) 10 +|=(% style="width: 171px;" %)Host|=(% style="width: 96px;" %)Available Addresses|=Start|=End|=Notes 11 +|(% style="width:171px" %)3-Series or 12 +4-Series processors|(% style="width:96px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks 13 +|(% style="width:171px" %)((( 14 +DIN-CENCN-2 or 15 +DIN-CENCN-2-POE 16 +)))|(% style="width:96px" %)((( 17 +25 per Net (50 total) 18 +)))|03|1B| 19 +|(% style="width:171px" %)ZUMNET-JBOX-16A-LV 20 +or ZUMNET-JBOX-DALI|(% style="width:96px" %)32|03|22|((( 21 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected 14 14 15 - ^^1^^ZUMNET-JBOXlocalcontrollercountsas adevice;only31 additionalZūmLink orCresnetdevices may beconnected.23 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] 16 16 ))) 17 -| | |03| | 18 18 19 19 Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device. 20 20 ... ... @@ -29,7 +29,8 @@ 29 29 |(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data + 30 30 |(% style="width:287px" %)Blue|(% style="width:380px" %)Data - 31 31 32 -= Terminations = 39 +(% class="wikigeneratedid" %) 40 +Terminations 33 33 34 34 Lorem ipsum dolor sit amet, 35 35
- 1704494079517-977.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.alexander\.mott@chiefintegrations\.com - Size
-
... ... @@ -1,0 +1,1 @@ 1 +439.7 KB - Content