To version 20.14
edited by Alexander Mott
on 2024/01/05 21:27
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -6,15 +6,17 @@
6 6  
7 7  Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host:
8 8  
9 -|=Host|=Available Addresses|=Start|=End|=Notes
10 -|3-Series or 4-Series processor | |03|FE|
11 -|DIN-CENCN-2(-POE)| |03| |
12 -|ZUMNET-JBOX-*|32^^1^^|03|22|(((
13 -Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]].
9 +|=(% style="width: 186px;" %)Host|=(% style="width: 62px;" %)Available Addresses|=Start|=End|=Notes
10 +|(% style="width:186px" %)3-Series or 4-Series processor |(% style="width:62px" %)252^^1^^|03|FE|^^1^^Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger networks
11 +|(% style="width:186px" %)DIN-CENCN-2(-POE)|(% style="width:62px" %)(((
12 +25 per Net (50 total)
13 +)))|03|1B|
14 +|(% style="width:186px" %)ZUMNET-JBOX-*|(% style="width:62px" %)32^^1^^|03|22|(((
15 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]
14 14  
15 -^^1^^ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected.
17 +^^1^^ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected
16 16  )))
17 -| | |03| |
19 +|(% style="width:186px" %)GLPAC-DIMFLV*|(% style="width:62px" %) |03| |
18 18  
19 19  Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device.
20 20