To version 20.28
edited by Alexander Mott
on 2024/01/05 22:27
Change comment: (Autosaved)

Summary

Details

Page properties
Content
... ... @@ -6,12 +6,23 @@
6 6  
7 7  Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host:
8 8  
9 -|=Host|=Available Addresses|=Start|=End|=Notes
10 -|3-Series or 4-Series processor | |03|FE|
11 -|DIN-CENCN-2(-POE)| |03| |
12 -|ZUMNET-JBOX-*| |03| |Zūm Link wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]].
13 -| | |03| |
9 +(% class="table-condensed" %)
10 +|=(% style="width: 171px;" %)Host|=(% style="width: 96px;" %)Available Addresses|=Start|=End|=Notes
11 +|(% style="width:171px" %)3-Series or
12 +4-Series processors|(% style="width:96px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks
13 +|(% style="width:171px" %)(((
14 +DIN-CENCN-2 or
15 +DIN-CENCN-2-POE
16 +)))|(% style="width:96px" %)(((
17 +25 per Net (50 total)
18 +)))|03|1B|
19 +|(% style="width:171px" %)ZUMNET-JBOX-16A-LV
20 +or ZUMNET-JBOX-DALI|(% style="width:96px" %)32|03|22|(((
21 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected
14 14  
23 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]
24 +)))
25 +
15 15  Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device.
16 16  
17 17  = Cabling =
... ... @@ -25,7 +25,8 @@
25 25  |(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data +
26 26  |(% style="width:287px" %)Blue|(% style="width:380px" %)Data -
27 27  
28 -= Terminations =
39 +(% class="wikigeneratedid" %)
40 +Terminations
29 29  
30 30  Lorem ipsum dolor sit amet,
31 31