Changes for page Cresnet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 23:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,17 +6,25 @@ 6 6 7 7 Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host: 8 8 9 -| | | | | 10 -| | | | | 11 -| | | | | 12 -| | | | | 13 -| | | | | 9 +(% class="table-condensed" %) 10 +|=(% style="width: 171px;" %)Host|=(% style="width: 96px;" %)Available Addresses|=Start|=End|=Notes 11 +|(% style="width:171px" %)3-Series or 12 +4-Series processors|(% style="width:96px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks 13 +|(% style="width:171px" %)((( 14 +DIN-CENCN-2 or 15 +DIN-CENCN-2-POE 16 +)))|(% style="width:96px" %)((( 17 +25 per Net (50 total) 18 +)))|03|1B| 19 +|(% style="width:171px" %)ZUMNET-JBOX-16A-LV 20 +or ZUMNET-JBOX-DALI|(% style="width:96px" %)32|03|22|((( 21 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected 14 14 23 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] 24 +))) 25 + 15 15 Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device. 16 16 17 - 18 -Zūm Link wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]. 19 - 20 20 = Cabling = 21 21 22 22 Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices and consists of a 4-wire, 2-pair cable available directly from Crestron with either plenum and non-plenum rated jackets. ... ... @@ -28,7 +28,8 @@ 28 28 |(% colspan="1" rowspan="2" style="width:307px" %)22 AWG shielded twisted pair|(% style="width:287px" %)White|(% style="width:380px" %)Data + 29 29 |(% style="width:287px" %)Blue|(% style="width:380px" %)Data - 30 30 31 -= Terminations = 39 +(% class="wikigeneratedid" %) 40 +Terminations 32 32 33 33 Lorem ipsum dolor sit amet, 34 34