Changes for page Cresnet Wiring Overview

Last modified by Alexander Mott on 2024/01/05 23:42

From version 20.11
edited by Alexander Mott
on 2024/01/05 21:12
Change comment: (Autosaved)
To version 20.15
edited by Alexander Mott
on 2024/01/05 21:31
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -6,17 +6,24 @@
6 6  
7 7  Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host:
8 8  
9 -| | | | |
10 -| | | | |
11 -| | | | |
12 -| | | | |
13 -| | | | |
9 +|=(% style="width: 186px;" %)Host|=(% style="width: 62px;" %)Available Addresses|=Start|=End|=Notes
10 +|(% style="width:186px" %)3-Series or
11 +4-Series processors|(% style="width:62px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks
12 +|(% style="width:186px" %)(((
13 +DIN-CENCN-2 or
14 +DIN-CENCN-2-POE
15 +)))|(% style="width:62px" %)(((
16 +25 per Net (50 total)
17 +)))|03|1B|
18 +|(% style="width:186px" %)ZUMNET-JBOX-16A-LV or
19 +ZUMNET-JBOX-DALI|(% style="width:62px" %)32|03|22|(((
20 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected
14 14  
22 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]
23 +)))
24 +
15 15  Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device.
16 16  
17 -
18 -Zūm Link wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]].
19 -
20 20  = Cabling =
21 21  
22 22  Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices and consists of a 4-wire, 2-pair cable available directly from Crestron with either plenum and non-plenum rated jackets.