Changes for page Cresnet Wiring Overview
Last modified by Alexander Mott on 2024/01/05 23:42
To version 20.15
edited by Alexander Mott
on 2024/01/05 21:31
on 2024/01/05 21:31
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -6,17 +6,24 @@ 6 6 7 7 Each job with Cresnet devices will have at least one Cresnet bus network. Every Cresnet bus network has a single //host// or //primary// device and one or more //client// or //secondary// devices (older materials may refer to hosts as //masters// and clients as //slaves//). Every Cresnet device on a Cresnet bus must be assigned a unique, one-byte hexadecimal Cresnet address. The range of available addresses is determined by the bus host: 8 8 9 -| | | | | 10 -| | | | | 11 -| | | | | 12 -| | | | | 13 -| | | | | 9 +|=(% style="width: 186px;" %)Host|=(% style="width: 62px;" %)Available Addresses|=Start|=End|=Notes 10 +|(% style="width:186px" %)3-Series or 11 +4-Series processors|(% style="width:62px" %)252|03|FE|Chief Integrations has experienced significant communications slowdowns on systems with more than 100 devices, and recommends using DIN-CENCN-2(-POE) or additional processors to break up larger Cresnet bus networks 12 +|(% style="width:186px" %)((( 13 +DIN-CENCN-2 or 14 +DIN-CENCN-2-POE 15 +)))|(% style="width:62px" %)((( 16 +25 per Net (50 total) 17 +)))|03|1B| 18 +|(% style="width:186px" %)ZUMNET-JBOX-16A-LV or 19 +ZUMNET-JBOX-DALI|(% style="width:62px" %)32|03|22|((( 20 +ZUMNET-JBOX local controller counts as a device; only 31 additional Zūm Link or Cresnet devices may be connected 14 14 22 +Zūm Link and Cresnet can be intermingled; more details are available [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]] 23 +))) 24 + 15 15 Power considerations also play a role in determining the number of Cresnet devices which can be supported on a Cresnet bus, however we will not cover them here due to the wide array of variables which impact power calculations and determining whether there is sufficient power for a given device. 16 16 17 - 18 -Zūm Link wiring is covered in more detail [[here>>doc:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.Zūm Wired Wiring Overview.WebHome]]. 19 - 20 20 = Cabling = 21 21 22 22 Cresnet cabling provides the physical infrastructure for communication between Crestron Cresnet devices and consists of a 4-wire, 2-pair cable available directly from Crestron with either plenum and non-plenum rated jackets.