Changes for page 0-10V Dimming Troubleshooting
Last modified by Alexander Mott on 2024/01/05 18:55
From version 30.1
edited by Alexander Mott
on 2024/01/05 18:55
on 2024/01/05 18:55
Change comment:
Renamed from xwiki:SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.0-10V Dimming Troubleshooting.WebHome
To version 20.1
edited by Alexander Mott
on 2022/09/19 16:12
on 2022/09/19 16:12
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide. Troubleshooting Guide.Hardware and Installation.WebHome1 +SHOWRUNNER™ Setup Guide.WebHome - Content
-
... ... @@ -1,3 +1,7 @@ 1 +{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 +{{toc/}} 3 +{{/box}} 4 + 1 1 (% class="row" %) 2 2 ((( 3 3 (% class="col-xs-12 col-sm-8" %) ... ... @@ -12,7 +12,7 @@ 12 12 1. Disconnect the 0-10V wiring to the fixtures 13 13 1. Connect a multimeter to the 0-10V dimming output of the module 14 14 1. Measure the 0-10V output at various brightness levels 15 -1*. If the system has been partially or fully commissioned, it may be possible to use the ShowRunnerCLC™ UI to adjust the brightness19 +1*. If the system has been partially or fully commissioned, it may be possible to use the showrunner™ UI to adjust the brightness 16 16 1*. Alternatively, some modules have physical buttons that can be used to adjust their brightness: 17 17 1**. Press the button to toggle the output on or off. A small LED light on the module will indicate current output on/off status. 18 18 1**. Once the output is on, press and hold the button to cycle dim the output (first press and hold will lower the output, subsequent press and holds will toggle between raising and lowering the output) ... ... @@ -43,7 +43,7 @@ 43 43 1. Identify the module and output that should be controlling the fixtures 44 44 1. Disconnect the 0-10V wiring to the fixtures 45 45 1. Toggle the module output on and off to verify it is switching the correct zone 46 -1*. If the system has been partially or fully commissioned, it may be possible to use the ShowRunnerCLC™ UI to toggle the module output50 +1*. If the system has been partially or fully commissioned, it may be possible to use the showrunner™ UI to toggle the module output 47 47 1*. Alternatively, some modules have physical buttons that can be used to toggle the output: 48 48 1**. Press the button to toggle the output on or off. A small LED light on the module will indicate current output on/off status. 49 49 1**. Once the output is on, press and hold the button to cycle dim the output (first press and hold will lower the output, subsequent press and holds will toggle between raising and lowering the output) ... ... @@ -173,12 +173,9 @@ 173 173 174 174 ))) 175 175 180 + 176 176 (% class="col-xs-12 col-sm-4" %) 177 177 ((( 178 -{{box title="**CONTENTS**"}} 179 -{{toc/}} 180 -{{/box}} 181 - 182 182 (% class="wikigeneratedid" id="HFigure1" %) 183 183 ((( 184 184 [[[[image:zumlink.png]]>>attach:zumlink.png]]