Changes for page 0-10V Dimming Troubleshooting
Last modified by Alexander Mott on 2024/01/05 18:55
From version 20.1
edited by Alexander Mott
on 2022/09/19 16:12
on 2022/09/19 16:12
Change comment:
There is no comment for this version
To version 31.2
edited by Alexander Mott
on 2024/01/05 18:55
on 2024/01/05 18:55
Change comment:
Update document after refactoring.
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.WebHome 1 +SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Troubleshooting.WebHome - Content
-
... ... @@ -1,7 +5,3 @@ 1 -{{box cssClass="floatinginfobox" title="**CONTENTS**"}} 2 -{{toc/}} 3 -{{/box}} 4 - 5 5 (% class="row" %) 6 6 ((( 7 7 (% class="col-xs-12 col-sm-8" %) ... ... @@ -16,7 +16,7 @@ 16 16 1. Disconnect the 0-10V wiring to the fixtures 17 17 1. Connect a multimeter to the 0-10V dimming output of the module 18 18 1. Measure the 0-10V output at various brightness levels 19 -1*. If the system has been partially or fully commissioned, it may be possible to use the showrunner™ UI to adjust the brightness15 +1*. If the system has been partially or fully commissioned, it may be possible to use the ShowRunnerCLC™ UI to adjust the brightness 20 20 1*. Alternatively, some modules have physical buttons that can be used to adjust their brightness: 21 21 1**. Press the button to toggle the output on or off. A small LED light on the module will indicate current output on/off status. 22 22 1**. Once the output is on, press and hold the button to cycle dim the output (first press and hold will lower the output, subsequent press and holds will toggle between raising and lowering the output) ... ... @@ -47,7 +47,7 @@ 47 47 1. Identify the module and output that should be controlling the fixtures 48 48 1. Disconnect the 0-10V wiring to the fixtures 49 49 1. Toggle the module output on and off to verify it is switching the correct zone 50 -1*. If the system has been partially or fully commissioned, it may be possible to use the showrunner™ UI to toggle the module output46 +1*. If the system has been partially or fully commissioned, it may be possible to use the ShowRunnerCLC™ UI to toggle the module output 51 51 1*. Alternatively, some modules have physical buttons that can be used to toggle the output: 52 52 1**. Press the button to toggle the output on or off. A small LED light on the module will indicate current output on/off status. 53 53 1**. Once the output is on, press and hold the button to cycle dim the output (first press and hold will lower the output, subsequent press and holds will toggle between raising and lowering the output) ... ... @@ -105,7 +105,7 @@ 105 105 106 106 On the front of the Zūm JBOX-16A-LV (outside the junction box) are two or three LEDs next to a black button. The LED labeled "TEST" will be green if the output is hot. The black button can be used to toggle the output on or off, and holding the button will cycle dim the 0-10V output. 107 107 108 -See //[[Figure 1>>WebHome||anchor="HFigure1"]]// for details. 104 +See //[[Figure 1>>SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.0-10V Dimming Troubleshooting.WebHome||anchor="HFigure1"]]// for details. 109 109 110 110 == CLX-2DIMFLV8 and CLX-2DIMFLV8-277 == 111 111 ... ... @@ -115,7 +115,7 @@ 115 115 116 116 On the front of 0-10V CLX modules are eight buttons corresponding to each of the eight outputs. Next to each button is a red LED indicating the current load status. The LED will be lit if the output is on. To the right of the LED is the 0-10V output for each channel, which can be easily unplugged for troubleshooting. The buttons can be used to toggle each channel independently, and holding the button will cycle dim the 0-10V output for that channel. 117 117 118 -See //[[Figure 2>>WebHome||anchor="HFigure2"]]// for details. 114 +See //[[Figure 2>>SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.0-10V Dimming Troubleshooting.WebHome||anchor="HFigure2"]]// for details. 119 119 120 120 == GL-EXP-DIMFLV-CN == 121 121 ... ... @@ -147,7 +147,7 @@ 147 147 148 148 The 0-10V outputs are located on the top right of the module. A small screwdriver is required to disconnect the dimming to the fixtures. 149 149 150 -See //[[Figure 3>>WebHome||anchor="HFigure3"]]// for details. 146 +See //[[Figure 3>>SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.0-10V Dimming Troubleshooting.WebHome||anchor="HFigure3"]]// for details. 151 151 152 152 == GLXP-DIMFLV8 (Discontinued) == 153 153 ... ... @@ -159,7 +159,7 @@ 159 159 160 160 The 0-10V outputs are split into the eight negative outputs and the eight positive outputs on the lower left of the module. A small screwdriver is required to disconnect the dimming to the fixtures. 161 161 162 -See //[[Figure 4>>WebHome||anchor="HFigure4"]]// for details. 158 +See //[[Figure 4>>SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Hardware and Installation.0-10V Dimming Troubleshooting.WebHome||anchor="HFigure4"]]// for details. 163 163 164 164 = Real World 0-10V Data = 165 165 ... ... @@ -177,9 +177,12 @@ 177 177 178 178 ))) 179 179 180 - 181 181 (% class="col-xs-12 col-sm-4" %) 182 182 ((( 178 +{{box title="**CONTENTS**"}} 179 +{{toc/}} 180 +{{/box}} 181 + 183 183 (% class="wikigeneratedid" id="HFigure1" %) 184 184 ((( 185 185 [[[[image:zumlink.png]]>>attach:zumlink.png]]