Changes for page Zummesh Dynamic White/CCT
Last modified by Austin Weygandt on 2025/10/09 15:46
From version 9.3
edited by Craig Lewis
on 2022/09/19 17:02
on 2022/09/19 17:02
Change comment:
Update document after refactoring.
To version 11.1
edited by Austin Weygandt
on 2025/10/09 15:46
on 2025/10/09 15:46
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ Setup Guide.Troubleshooting Guide. Software andProgramming.Troubleshooting.WebHome1 +SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. craig\.lewis@chiefintegrations\.com1 +XWiki.austin\.weygandt@chiefintegrations\.com - Content
-
... ... @@ -1,5 +1,16 @@ 1 -Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunner requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunner will be ignored. 1 +{{warning}} 2 +Caveats: 2 2 4 +* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 5 +* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 6 +* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes) 7 +* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 8 +* Setup must be done from the gateway console 9 +* Loads must be manually changed to BusIndex 3 in the config 10 +{{/warning}} 11 + 12 +Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored. 13 + 3 3 ==== Typical Setup for up to 6 zones, 5 fixture types: ==== 4 4 5 5 (% border="1" style="width:600px" %) ... ... @@ -21,14 +21,6 @@ 21 21 |14|-|-|Intensity 22 22 |15|-|-|Color 23 23 24 -==== Caveats: ==== 25 - 26 -* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 27 -* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 28 -* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes) 29 -* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 30 -* Setup must be done from the gateway console 31 - 32 32 ==== Setup Steps: ==== 33 33 34 34 1. Address all DALI drivers attached to the JBOX. This can be done via the gateway console or via the Zum app on iOS/Android.