Changes for page Zummesh Dynamic White/CCT
Last modified by Mark Kohlmann on 2026/01/08 20:58
From version 6.1
edited by Mark Kohlmann
on 2021/09/07 22:45
on 2021/09/07 22:45
Change comment:
There is no comment for this version
To version 16.1
edited by Mark Kohlmann
on 2026/01/08 20:58
on 2026/01/08 20:58
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ UserGuide& Wiki.Troubleshooting.WebHome1 +SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.WebHome - Content
-
... ... @@ -1,59 +1,79 @@ 1 -Zum wireless supports dynamic white using DALI Groups 9-16 (8 to 15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunner requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunner will be ignored. 1 +{{warning}} 2 +Caveats: 2 2 3 -==== Typical Setup for up to 6 zones, 5 fixture types: ==== 4 +* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 5 +* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2/DIN-DLI if more capabilities are needed. 6 +* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 on the Zum app (0 based - 1,3,5,7,9,11,13,15 for ShowRunner/console purposes) 7 +* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 8 +* Setup must be done from the gateway console 9 +* **Loads must be manually changed to BusIndex 3 in the ShowRunner config or added from the UI with BusIndex 3. Normally DALI loads are BusIndex 2.** 10 +{{/warning}} 4 4 5 - ========12 +Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for ShowRunner/console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored. 6 6 7 -(% border="1" style="width:500px" %) 14 +==== Typical Setup for up to 6 zones, 5 fixture types: ==== 15 + 16 +(% border="1" style="width:600px" %) 8 8 |=DALI Group|=Name|=Fixture Type|=Control Type 9 9 |0|Downlights, Main|F0|Intensity 10 -|1| Accent Lights|F1a|Intensity11 -|2| Spot Lights|F3|Intensity12 -|3| Troffers|F4c|Intensity13 -|4|Li near|F9|Intensity14 -|5| Downlights@ Screen|F0|Intensity15 -|6| -|-|Intensity16 -|7| -|-|Intensity17 -|8| Downlights CCT|F0|Color18 -|9| AccentLights CCT|F1a|Color19 -|10| Spot LightsCCT|F3|Color20 -|11| Troffers CCT|F4c|Color21 -|12| Linear CCT|F9|Color19 +|1|Downlights, Main/Screen CCT|F0|Color 20 +|2|Accent Lights|F1a|Intensity 21 +|3|Accent Lights CCT|F1a|Color 22 +|4|Spot Lights|F3|Intensity 23 +|5|Spot Lights CCT|F3|Color 24 +|6|Troffers|F4c|Intensity 25 +|7|Troffers CCT|F4c|Color 26 +|8|Linear|F9|Intensity 27 +|9|Linear|F9|Color 28 +|10|Downlights @ Screen|F0|Intensity 29 +|11|-|-|Color 30 +|12|-|-|Intensity 22 22 |13|-|-|Color 23 -|14|-|-| Color32 +|14|-|-|Intensity 24 24 |15|-|-|Color 25 25 26 -==== Caveats: ====35 +==== Setup Steps: ==== 27 27 28 -* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 29 -* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 30 -* Supports up to 8 CCT channels, DALI Groups 9-16 (8 to 15 for console purposes) 31 -* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 32 -* Setup must be done from the gateway console 33 33 34 - ====SetupSteps:====38 +If your DALI groups are already commissioned and you need to specify the groups for color (Examples shown for group 7): 35 35 36 -1. Address all DALI drivers attached to the JBOX. This can be done via the gateway console or via the Zum app on iOS/Android. 37 -Command: //rfrcon <**NetbridgeID**> DALIGLOBALADDRESS <**Action**>// 40 +1. Modify DALI Group to color, only needed if step 2 was not done. If step 2 was performed skip this step. 41 +##Command: //rfrcon <**NetbridgeID**> DALIGROUPSETTWRITE <**GroupID**> 14 <**GroupType**>// 42 +**GroupID: **0 to 15 43 +**GroupType:** 0=Intensity, 1=Color 44 +Example: (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPSETTWRITE 7 14 1//## 45 +1. Set Scene settings for Color Support. Enables or uses a fixed value for color temperature on color groups. This must be done for all scenes that will be used. 46 +##Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**Action**> <**FadeTime**> 47 +**GroupID**: 0 to 15 (odd for color) 48 +**SceneID**: Scene number (1 to 16) 49 +**SceneLevel**: 255 for ShowRunner control, 0-254 for fixed scene level 50 +**Action**: 0=Remove Scene, 1=Add Scene 51 +**FadeTime**: Fade time in 1/10th of a second 52 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 7 1 255 1 10// 53 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 7 2 255 1 10//## 54 +1. Change the area to a different scene and then back to a scene that has color enabled to permit the receiving of color commands. 55 + 56 +If Starting from scratch without having been commissioned in the Zum App (Examples shown for group 7): 57 + 58 +1. ((( 59 +Address all DALI drivers attached to the JBOX. This can be done via the gateway console or via the Zum app on iOS/Android. 60 +##Command: //rfrcon <**NetbridgeID**> DALIGLOBALADDRESS <**Action**>// 38 38 **Action**: 0=stop, 1=start, 3=get status 39 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGLOBALADDRESS 1// 62 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGLOBALADDRESS 1//## 63 +))) 40 40 1. Create DALI Groups. If group already exists then go to step 3. This must be done from the gateway console. 41 -Command: //rfrcon <**NetbridgeID**> DALIGROUPADDDELETE <**GroupID**> <**Operation**> <**GroupName**>// 65 +##Command: //rfrcon <**NetbridgeID**> DALIGROUPADDDELETE <**GroupID**> <**Operation**> <**GroupName**>// 42 42 **GroupID: **0 to 15 43 43 **Operation:** 0=Delete Group, 1=Add Intensity Group, 3=Add Color Group 44 44 **GroupName: **Name of the group, no spaces, 16 characters max 45 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPADDDELETE 8 3 TypeF1-Color// 46 -1. Modify DALI Group to color, only needed if step 2 was not done. If step 2 was performed skip this step. 47 -Command: //rfrcon <**NetbridgeID**> DALIGROUPSETTWRITE <**GroupID**> 14 <**GroupType**>// 48 -**GroupID: **0 to 15 49 -**GroupType:** 0=Intensity, 1=Color 50 -Example: (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPSETTWRITE 8 14 1// 51 -1. Set Scene settings for Color Support. Enables or uses a fixed value for color temperature on color groups. 52 -Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**Action**> <**FadeTime**> 53 -**GroupID**: 8 to 15 69 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPADDDELETE 7 3 TypeF1-Color//## 70 +1. Set Scene settings for Color Support. Enables or uses a fixed value for color temperature on color groups. This must be done for all scenes that will be used. 71 +##Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**Action**> <**FadeTime**> 72 +**GroupID**: 0 to 15 (odd for color) 54 54 **SceneID**: Scene number (1 to 16) 55 55 **SceneLevel**: 255 for ShowRunner control, 0-254 for fixed scene level 56 56 **Action**: 0=Remove Scene, 1=Add Scene 57 57 **FadeTime**: Fade time in 1/10th of a second 58 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 8 1 255 1 10// 59 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 15 1 255 1 10// 77 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 7 1 255 1 10// 78 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 7 2 255 1 10//## 79 +1. Change the area to a different scene and then back to a scene that has color enabled to permit the receiving of color commands.