Changes for page Zummesh Dynamic White/CCT
Last modified by Austin Weygandt on 2025/10/09 15:46
From version 4.1
edited by Mark Kohlmann
on 2021/09/07 22:43
on 2021/09/07 22:43
Change comment:
There is no comment for this version
To version 11.1
edited by Austin Weygandt
on 2025/10/09 15:46
on 2025/10/09 15:46
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ UserGuide& Wiki.Troubleshooting.WebHome1 +SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.austin\.weygandt@chiefintegrations\.com - Content
-
... ... @@ -1,36 +1,37 @@ 1 -Zum wireless supports dynamic white using DALI Groups 9-16 (8 to 15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunner requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunner will be ignored. 1 +{{warning}} 2 +Caveats: 2 2 3 -==== Typical Setup for up to 6 zones, 5 fixture types: ==== 4 +* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 5 +* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 6 +* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes) 7 +* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 8 +* Setup must be done from the gateway console 9 +* Loads must be manually changed to BusIndex 3 in the config 10 +{{/warning}} 4 4 5 - ========12 +Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored. 6 6 7 -(% border="1" style="width:500px" %) 14 +==== Typical Setup for up to 6 zones, 5 fixture types: ==== 15 + 16 +(% border="1" style="width:600px" %) 8 8 |=DALI Group|=Name|=Fixture Type|=Control Type 9 9 |0|Downlights, Main|F0|Intensity 10 -|1| Accent Lights|F1a|Intensity11 -|2| Spot Lights|F3|Intensity12 -|3| Troffers|F4c|Intensity13 -|4|Li near|F9|Intensity14 -|5| Downlights@ Screen|F0|Intensity15 -|6| -|-|Intensity16 -|7| -|-|Intensity17 -|8| Downlights CCT|F0|Color18 -|9| AccentLights CCT|F1a|Color19 -|10| Spot LightsCCT|F3|Color20 -|11| Troffers CCT|F4c|Color21 -|12| Linear CCT|F9|Color19 +|1|Downlights, Main/Screen CCT|F0|Color 20 +|2|Accent Lights|F1a|Intensity 21 +|3|Accent Lights CCT|F1a|Color 22 +|4|Spot Lights|F3|Intensity 23 +|5|Spot Lights CCT|F3|Color 24 +|6|Troffers|F4c|Intensity 25 +|7|Troffers CCT|F4c|Color 26 +|8|Linear|F9|Intensity 27 +|9|Linear|F9|Color 28 +|10|Downlights @ Screen|F0|Intensity 29 +|11|-|-|Color 30 +|12|-|-|Intensity 22 22 |13|-|-|Color 23 -|14|-|-| Color32 +|14|-|-|Intensity 24 24 |15|-|-|Color 25 25 26 -==== Caveats: ==== 27 - 28 -* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 29 -* NETBRIDGE must be attached to the ZUMMESH-JOBX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 30 -* Supports up to 8 CCT channels, DALI Groups 9-16 (8 to 15 for console purposes) 31 -* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 32 -* Setup must be done from the gateway console 33 - 34 34 ==== Setup Steps: ==== 35 35 36 36 1. Address all DALI drivers attached to the JBOX. This can be done via the gateway console or via the Zum app on iOS/Android. ... ... @@ -50,10 +50,10 @@ 50 50 Example: (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPSETTWRITE 8 14 1// 51 51 1. Set Scene settings for Color Support. Enables or uses a fixed value for color temperature on color groups. 52 52 Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**Action**> <**FadeTime**> 53 -**GroupID**: 8to 1554 +**GroupID**: 0 to 15 (odd for color) 54 54 **SceneID**: Scene number (1 to 16) 55 55 **SceneLevel**: 255 for ShowRunner control, 0-254 for fixed scene level 56 56 **Action**: 0=Remove Scene, 1=Add Scene 57 57 **FadeTime**: Fade time in 1/10th of a second 58 58 Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 8 1 255 1 10// 59 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 15 1 255 810//60 +Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 15 1 255 1 10//