Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. mark\.kohlmann@chiefintegrations\.com1 +XWiki.austin\.weygandt@chiefintegrations\.com - Content
-
... ... @@ -2,14 +2,14 @@ 2 2 Caveats: 3 3 4 4 * Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 5 -* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 /DIN-DLIif more capabilities are needed.6 -* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 on the Zum app(0 based -1,3,5,7,9,11,13,15 forShowRunner/consolepurposes)5 +* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 6 +* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes) 7 7 * Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 8 8 * Setup must be done from the gateway console 9 -* **Loads must be manually changed to BusIndex 3 in the configor added from the UI with BusIndex 3. Normally DALI loads are BusIndex 2.**9 +* Loads must be manually changed to BusIndex 3 in the config 10 10 {{/warning}} 11 11 12 -Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for showrunner/console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored.12 +Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored. 13 13 14 14 ==== Typical Setup for up to 6 zones, 5 fixture types: ==== 15 15