Changes for page Zummesh Dynamic White/CCT
Last modified by Austin Weygandt on 2025/10/09 15:46
From version 11.1
edited by Austin Weygandt
on 2025/10/09 15:46
on 2025/10/09 15:46
Change comment:
There is no comment for this version
To version 1.5
edited by Mark Kohlmann
on 2021/09/07 18:21
on 2021/09/07 18:21
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -SHOWRUNNER™ SetupGuide.TroubleshootingGuide.Advanced Tools.WebHome1 +SHOWRUNNER™ User Guide & Wiki.Troubleshooting.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki.a ustin\.weygandt@chiefintegrations\.com1 +XWiki.mark\.kohlmann@chiefintegrations\.com - Content
-
... ... @@ -1,37 +1,35 @@ 1 -{{warning}} 2 -Caveats: 1 +Zum wireless supports dynamic white using DALI Groups 9-16 (8 to 15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunner requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunner will be ignored. 3 3 4 -* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 5 -* NETBRIDGE must be attached to the ZUMMESH-JBOX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 6 -* Supports up to 8 CCT channels, DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes) 7 -* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 8 -* Setup must be done from the gateway console 9 -* Loads must be manually changed to BusIndex 3 in the config 10 -{{/warning}} 3 +==== Typical Setup for up to 6 zones, 5 fixture types: 4 + ==== 11 11 12 -Zum wireless supports dynamic white using DALI Groups 2,4,6,8,10,12,14,16 (1,3,5,7,9,11,13,15 for console purposes). Setup must be performed manually on the NETBRIDGE. Once done, ShowRunner can use the CCT channels to provide CCT data to the fixtures. Input from ShowRunnerCLC™ requires setting the scene recall for the CCT group to 255. Any value of 0-254 will be sent to the CCT channel directly and the input from ShowRunnerCLC™ will be ignored. 13 - 14 -==== Typical Setup for up to 6 zones, 5 fixture types: ==== 15 - 16 -(% border="1" style="width:600px" %) 6 +(% border="1" style="width:500px" %) 17 17 |=DALI Group|=Name|=Fixture Type|=Control Type 18 18 |0|Downlights, Main|F0|Intensity 19 -|1| Downlights, Main/ScreenCCT|F0|Color20 -|2| Accent Lights|F1a|Intensity21 -|3| Accent LightsCCT|F1a|Color22 -|4| SpotLights|F3|Intensity23 -|5| Spot LightsCCT|F3|Color24 -|6| Troffers|F4c|Intensity25 -|7| Troffers CCT|F4c|Color26 -|8| Linear|F9|Intensity27 -|9|Li near|F9|Color28 -|10| Downlights@ Screen|F0|Intensity29 -|11| -|-|Color30 -|12| -|-|Intensity9 +|1|Accent Lights|F1a|Intensity 10 +|2|Spot Lights|F3|Intensity 11 +|3|Troffers|F4c|Intensity 12 +|4|Linear|F9|Intensity 13 +|5|Downlights @ Screen|F0|Intensity 14 +|6|-|-|Intensity 15 +|7|-|-|Intensity 16 +|8|Downlights CCT|F0|Color 17 +|9|Accent Lights CCT|F1a|Color 18 +|10|Spot Lights CCT|F3|Color 19 +|11|Troffers CCT|F4c|Color 20 +|12|Linear CCT|F9|Color 31 31 |13|-|-|Color 32 -|14|-|-| Intensity22 +|14|-|-|Color 33 33 |15|-|-|Color 34 34 25 +==== Caveats: ==== 26 + 27 +* Only intensity/CCT fixtures are supported. This will not work with warm/cool fixtures. 28 +* NETBRIDGE must be attached to the ZUMMESH-JOBX-DALI. Only 1 ZUMMESH-JBOX-DALI is supported per room. Use Zum Wired or DIN-DALI-2 if more capabilities are needed. 29 +* Supports up to 8 CCT channels, DALI Groups 9-16 (8 to 15 for console purposes) 30 +* Zum Scene must have the CCT channel set to 255 to accept input from ShowRunner. Values of 0-254 will be sent directly to the group as fixed colors. 31 +* Setup must be done from the gateway console 32 + 35 35 ==== Setup Steps: ==== 36 36 37 37 1. Address all DALI drivers attached to the JBOX. This can be done via the gateway console or via the Zum app on iOS/Android. ... ... @@ -48,13 +48,6 @@ 48 48 Command: //rfrcon <**NetbridgeID**> DALIGROUPSETTWRITE <**GroupID**> 14 <**GroupType**>// 49 49 **GroupID: **0 to 15 50 50 **GroupType:** 0=Intensity, 1=Color 51 -Example: (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPSETTWRITE 8 14 1// 52 -1. Set Scene settings for Color Support. Enables or uses a fixed value for color temperature on color groups. 53 -Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**Action**> <**FadeTime**> 54 -**GroupID**: 0 to 15 (odd for color) 55 -**SceneID**: Scene number (1 to 16) 56 -**SceneLevel**: 255 for ShowRunner control, 0-254 for fixed scene level 57 -**Action**: 0=Remove Scene, 1=Add Scene 58 -**FadeTime**: Fade time in 1/10th of a second 59 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 8 1 255 1 10// 60 -Example (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPCOMMAND 4 15 1 255 1 10// 49 +Example: rfrcon (NETBRIDGE RF-ID 1A): //rfrcon 1A DALIGROUPSETTWRITE 8 14 1// 50 +1. Set Scene settings for Color Support: 51 +Command: rfrcon <**NetbridgeID**> DALIGROUPCOMMAND 4 <**GroupID**> <**SceneID**> <**SceneLevel**> <**AnalogInput**> <**FadeTime**>