GLPAC (Cresnet)
Version 11.6 by Craig Lewis on 2022/08/18 16:56
Older systems with GLPACs wired to the processor via Cresnet can be added by created a program for slot 2.
- Create a SIMPL windows program
- Add the GLPAC-DIMFLV8 (Cresnet) to the appropriate Cresnet IDs
- Define the Level In and Level Out analog signals on the GLPAC Remote Standard Intersystem Communications
- Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID
- In Device Settings, set the Default IP Address to 127.0.0.2 (Loop back address)
- Copy the GLPACs Level In and Level Out signals and paste them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals
- In the showrunner config, the lighting controller will be defined with the following settings
- Controller Type = "3SeriesEisc"
- ID and Device Connection Id = IP ID used
- Properties Value = "127.0.0.2"
- Loads Index for each load = the analog joins defined in the SIMPL program EISC Analog Symbols