Changes for page Legacy Hardware (Cresnet)

Last modified by Craig Lewis on 2024/12/02 14:48

From version 19.1
edited by Craig Lewis
on 2024/12/02 14:48
Change comment: There is no comment for this version
To version 11.2
edited by Craig Lewis
on 2022/08/18 16:48
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -Legacy Hardware (Cresnet)
1 +GLPAC (Cresnet)
Parent
... ... @@ -1,1 +1,1 @@
1 -SHOWRUNNER™ Setup Guide.Troubleshooting Guide.Advanced Tools.WebHome
1 +SHOWRUNNER™ User Guide & Wiki.Troubleshooting.WebHome
Content
... ... @@ -1,29 +1,18 @@
1 -Older systems with Legacy Hardware, such as CNLDM-6 or GLPACs, wired to the processor via Cresnet can be added to ShowRunnerCLC™ by created a program for slot 2.
1 +Older systems with GLPACs wired back to the processor via Cresnet can be added by created a program for slot 2.
2 2  
3 +
3 3  * Create a SIMPL windows program
4 4  * Add the GLPAC-DIMFLV8 (Cresnet) to the appropriate Cresnet IDs
5 -* Define the Level In and Level Out analog signals on the GLPAC Remote Standard Intersystem Communications
6 +* Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID
7 +* Define the Level In and Level Out analog signals on each of the GLPAC Remote Standard Intersystem Communications
6 6  
7 7  [[image:1660773651340-476.png]]
8 8  
9 -* Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID
10 -* In Device Settings, set the Default IP Address to 127.0.0.2 (Loop back address)
11 +* Copy the Level In and Level Out signals and past them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals
11 11  
12 -[[image:image-20220817145415-2.png]]
13 -
14 -* Copy the GLPACs Level In and Level Out signals and paste them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals
15 -
16 16  [[image:1660773665229-324.png]]
17 17  
18 -* In the showrunner™ config, the lighting controller will be defined with the following settings
19 -** Controller Type = "3SeriesEisc"
20 -** ID and Device Connection Id = IP ID used
21 -** Properties Value = "127.0.0.2"
22 -** Loads Index for each load = the analog joins defined in the SIMPL program EISC Analog signals
15 +[[image:image-20220817145415-2.png]]
23 23  
24 -[[image:image-20220817145415-4.png]]
25 25  
26 -
27 -GLPACs on Cresnet directly to the processor can be added to ShowRunnerCLC™, without requiring a second programming slot, by deleting the properties lines and setting the Model to:
28 -
29 - "Model": "GLPAC-DIMFLV8_Cresnet",
18 +[[image:image-20220817145415-4.png]]