... ... @@ -1,13 +1,26 @@
1 -
1 +Older systems with GLPACs wired back to the processor via Cresnet can be added by created a program for slot 2.
2 2  
3 +
4 +* Create a SIMPL windows program
5 +* Add the GLPAC-DIMFLV8 (Cresnet) to the appropriate Cresnet IDs
6 +* Define the Level In and Level Out analog signals on each of the GLPAC Remote Standard Intersystem Communications
7 +
3 3  [[image:1660773651340-476.png]]
4 4  
10 +* Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID
11 +* In Device Settings, set the Default IP Address to 127.0.0.2 (Loop back address)
5 5  
6 6  [[image:image-20220817145415-2.png]]
7 7  
15 +* Copy the GLPACs Level In and Level Out signals and paste them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals
8 8  
9 -
10 10  [[image:1660773665229-324.png]]
11 11  
19 +* In the showrunner config, the lighting controller will be defined with the following settings
20 +** Controller Type = "3SeriesEisc"
21 +** ID and Device Connection Id = IP ID used
22 +** Properties Value = "127.0.0.2"
23 +** Loads Index for each load = the analog joins defined in the SIMPL program EISC Analog Symbols
12 12  
25 +
13 13  [[image:image-20220817145415-4.png]]