... ... @@ -1,13 +1,21 @@
1 -
1 +Older systems with GLPACs wired back to the processor via Cresnet can be added by created a program for slot 2.
2 2  
3 -[[image:1660773542268-243.png]]
4 4  
4 +* Create a SIMPL windows program
5 +* Add the GLPAC-DIMFLV8 (Cresnet) to the appropriate Cresnet IDs
6 +* Define the Level In and Level Out analog signals on each of the GLPAC Remote Standard Intersystem Communications
5 5  
8 +[[image:1660773651340-476.png]]
9 +
10 +* Add a 3 Series TCP/IP Ethernet Intersystem Communications to the appropriate Ethernet ID
11 +* In Device Settings, set the Default IP Address to 127.0.0.2 (Loop back address)
12 +
6 6  [[image:image-20220817145415-2.png]]
7 7  
15 +* Copy the GLPACs Level In and Level Out signals and paste them to the 3 Series TCP/IP Ethernet Intersystem Communications Analog signals
8 8  
17 +[[image:1660773665229-324.png]]
9 9  
10 -[[image:1660773463839-697.png||height="558" width="885"]]
11 11  
12 12  
13 13  [[image:image-20220817145415-4.png]]