Changes for page Updating Firmware

Last modified by Alexander Mott on 2024/10/15 14:55

From version 4.1
edited by Alexander Mott
on 2023/12/11 20:36
Change comment: Uploaded new attachment "1702327000173-930.png", version {1}
To version 3.1
edited by Alexander Mott
on 2023/12/11 20:34
Change comment: Uploaded new attachment "1702326885738-296.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -2,30 +2,20 @@
2 2  {{toc/}}
3 3  {{/box}}
4 4  
5 -ShowRunnerCLC™ is tested against the latest Crestron firmware releases, and as such it is recommended to update all device firmware whenever starting up a job. While firmware updates can be performed at any time, it is recommended to update network devices after their network settings have been configured but before loading the ShowRunnerCLC™ program and starting up the job in order to avoid any potential bugs that may result from using outdated firmware. Controlled hardware should be updated once all devices on any given Cresnet/ZUMLINK bus or wireless gateway are online and uniquely addressed. Any communication issues on the bus or gateway should also be resolved prior to updating firmware.
5 +ShowRunnerCLC™ is tested against the latest Crestron firmware releases, and as such it is recommended to update all device firmware whenever starting up a job. While firmware updates can be performed at any time, it is typically recommended to update network devices after their network settings have been configured (to take advantage of increased file transfer speed over Ethernet compared to USB), but before loading the ShowRunnerCLC™ program and starting up the job (to avoid any potential bugs that may result from using outdated firmware).
6 6  
7 -Current Crestron firmware can be downloaded from [[Crestron's website>>https://www.crestron.com/Support/Search-Results?c=4]]. Old firmware releases can be downloaded using an SFTP client (such as FileZilla or WinSCP) and connecting to "ftp.crestron.com"
8 -
9 9  = Network Devices =
10 10  
11 -Networked devices (i.e. devices connected via Ethernet to the LAN or Control Subnet) should always be updated when starting up a job. You can check the current firmware version of most network devices by running the ##ver## command in Text Console or by exporting a Device Summary using the Device Discovery Tool.
9 +Networked devices (i.e. devices connected to the LAN or Control Subnet)
12 12  
13 -While these devices can be updated over USB, it is recommended to update these devices over Ethernet whenever possible in order to take advantage of increased file transfer speed of Ethernet and to enable updating multiple devices at once. Since most network devices will reboot as a part of the firmware update process, **it is important to be mindful of the order in which devices are updated to avoid losing connection to a device while in the middle of a file transfer**. For example, if you have several CEN-GWEXERs that are connected to a CEN-SWPOE-16, it is important to either update the CEN-SWPOE-16 //before// starting the update for any of the CEN-GWEXERs, **or** wait to update the CEN-SWPOE-16 until //after// all of the CEN-GWEXERs are done updating. If you update all devices simultaneously, you risk damage to the CEN-GWEXERs as a result of losing power mid-update due to the CEN-SWPOE-16 rebooting.
11 +== Sub 1 ==
14 14  
15 -== SFTP and SSH (Processors) ==
13 +Lorem
16 16  
17 -Due to the large file size for processor firmware, the most efficient method of updating firmware is to use dedicated third-party SFTP and SSH clients rather than built-in Toolbox functions. This allows for rapidly transferring the large firmware file to the device and then running the update without locking up Toolbox and preventing you from working on other devices while the firmware update is performed.
15 +== Sub 2 ==
18 18  
19 -* Open an SFTP client such as FileZilla or WinSCP (pictured) and connect to the processor at port 22
20 -[[image:1702319634460-252.png||height="309" width="437"]]
21 -* Transfer the firmware file to the "firmware" folder on the processor
22 -[[image:1702326885738-296.png||height="308" width="437"]]
23 -* asdf
17 +Lorem
24 24  
25 -== Package Update Tool (.puf) ==
26 -
27 -Crestron's Package Update Tool is the most convenient way of performing firmware updates for devices that use .puf files for firmware. While the Package Update Tool can be opened from within Crestron Toolbox, we recommend just double-clicking the .puf file to open the tool directly. When updating firmware with the Package Update Tool in Toolbox, the tool will lock Toolbox and only allow updating one device at a time
28 -
29 29  == Sub 2 ==
30 30  
31 31  Lorem
... ... @@ -32,7 +32,7 @@
32 32  
33 33  = Controlled Hardware =
34 34  
35 -Controlled hardware such as Cresnet and infinetEX devices are less frequently updated, but nonetheless will occasionally require firmware updates. ZUMLINK devices should always be updated, but these devices are automatically updated whenever their host ZUMNET device is updated as long as the ZUMLINK device is online and uniquely addressed.
25 +Lorem
36 36  
37 37  == Sub 1 ==
38 38  
1702327000173-930.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,1 +1,0 @@
1 -24.9 KB
Content