Changes for page Updating Firmware

Last modified by Alexander Mott on 2024/10/15 14:55

From version 24.1
edited by Alexander Mott
on 2023/12/11 21:17
Change comment: Uploaded new attachment "fuf2.png", version {1}
To version 26.1
edited by Alexander Mott
on 2023/12/11 21:18
Change comment: Deleted image "1702328931005-123.png"

Summary

Details

Page properties
Content
... ... @@ -44,6 +44,16 @@
44 44  
45 45  While most networked devices will use .puf files for firmware updates, some devices (such as DIN-DALI-2) will use .zip files. In these instances, the Package Update Tool will not work to update the firmware and you must instead use the "Functions..." menu to select and load the firmware.
46 46  
47 +* Connect to the device to be updated in Toolbox using a tool such as Text Console and open the Firmware dialog using one of the methods below: 
48 +** Click the Quick Functions lighting bolt icon and select "Firmware..." from the dropdown menu
49 +** At the top of the Toolbox window, navigate to Functions > Firmware... > Firmware...
50 +* Click the "Browse..." button and select the firmware .zip file
51 +[[image:fuf1.png||height="222" width="547"]]
52 +* Click the "Send" button to begin the firmware update
53 +[[image:fuf2.png||height="218" width="540"]]
54 +* asdf
55 +* asdf
56 +
47 47  = Controlled Hardware =
48 48  
49 49  Controlled hardware such as Cresnet and infinetEX devices are less frequently updated, but nonetheless will occasionally require firmware updates. ZUMLINK devices should always be updated, but these devices are automatically updated whenever their host ZUMNET device is updated as long as the ZUMLINK device is online and uniquely addressed.
1702328931005-123.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.alexander\.mott@chiefintegrations\.com
Size
... ... @@ -1,1 +1,0 @@
1 -11.7 KB
Content