... ... @@ -1,5 +1,7 @@
1 1  {{warning}}
2 2  TSW-xx70 firmware versions 2.001.0058 and above require a pingable gateway be specified in order to use static IP settings. If no default gateway is set, or the default gateway cannot be pinged, then odd network behavior and system instability may result. Pingability of a given address can be checked using the console command: ##ping [IP address]##
3 +
4 +All TSW-xx70 touchscreens require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations provide assistance if the credentials are not known. The only way to connect to a device for which the credentials have been lost is to factory reset the device, which may require redoing the start-up from scratch. **​​​​