1 +{{warning}}
2 +TSW-xx70 firmware versions 2.001.0058 and above require a pingable gateway be specified in order to use static IP settings. If no default gateway is set, or the default gateway cannot be pinged, then odd network behavior and system instability may result.
3 +{{/warning}}
4 +
1 1  === TSW Touchscreens with SHOWRUNNER™ ===
2 2  
3 3  TSWs touchscreens allow end users and technicians access to the SHOWRUNNER™ XPanel UI for both initial startup and daily use. Once the TSW has been configured and the SHOWRUNNER™ project has been loaded to it, it is possible to restrict what features can be accessed without entering a PIN code by navigating to Settings>Security Settings on the TSW. If the User Passcode is enabled, then a PIN will be required to access any of the touchscreen's UI. If the Setup Passcode is enabled, then the main Area Overview menu will be accessible, but anything in the Settings menu and beyond will require a PIN.
... ... @@ -36,6 +36,7 @@
36 36  ** Update IP table: ##addm (% style="color:olive" %)**10**(%%) (% style="color:orange" %)**10.0.0.10**(%%)##
37 37  ** Set hostname: ##host (% style="color:purple" %)**TSW-L1**(%%)##
38 38  ** Reboot the TSW: ##reboot##
43 +* Note that TSW-xx70 firmware versions 2.001.0058 and above require a pingable gateway be specified for static IP settings. If no default gateway is set, or the default gateway cannot be pinged, then you are very likely to experience odd network behavior and system instability.
39 39  
40 40  === Load the SHOWRUNNER™ Project ===
41 41