Changes for page Processor Setup
Last modified by Alexander Mott on 2024/12/02 19:04
From version 6.1
edited by Alexander Mott
on 2022/06/09 20:46
on 2022/06/09 20:46
Change comment:
Uploaded new attachment "1654807593390-193.png", version {1}
To version 7.1
edited by Alexander Mott
on 2022/06/09 21:41
on 2022/06/09 21:41
Change comment:
There is no comment for this version
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -23,11 +23,10 @@ 23 23 24 24 [[https:~~/~~/www.youtube.com/watch?v=H8CLZ7bp0eI>>url:https://www.youtube.com/watch?v=H8CLZ7bp0eI]] 25 25 26 -=== IP Configuration and Program Load (Per Processor)===26 +=== IP Configuration === 27 27 28 -* Obtain the latest build of SHOWRUNNER™ [[https:~~/~~/files.chiefintegrations.com/s/WHNzXrrZbB5jC3E>>url:https://files.chiefintegrations.com/s/WHNzXrrZbB5jC3E]] 29 29 * Connect to the processor via USB and set the processor’s IP Address per your network requirements 30 -** When connecting to a 4- series processor or a 3-series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user29 +** When connecting to a 4-Series processor or a 3-Series processor with authentication enabled for the first time, it will prompt for the creation of an admin-level CWS user 31 31 *** Input the desired username and password into the dialog box. Save this login information, as it is not possible to recover if it is lost or forgotten 32 32 *** In the event that the processor does not allow you to log in with the chosen credentials (i.e. it repeatedly prompts for credentials) 33 33 **** Attempt to log in with username "crestron" and no password ... ... @@ -53,43 +53,79 @@ 53 53 *** Set routing to "Manual" with the start address and subnet size 54 54 *** E.g., a setting of "10.0.0.0/24" will have the processor at 10.0.0.1 with an IP mask of 255.255.255.0 and a default gateway and DNS server at 10.0.0.2 55 55 ** The Control Subnet can also be configured using Text Console command: ##csrouterprefix 10.0.0.0/24## 55 +* If the job has multiple processors, then these steps must be repeated for all processors on the job 56 +** For jobs with Central Control, the IP addresses of the processors matters 57 +** Chief Integrations will provide an SRTakeoff.xlsx spreadsheet with an IP Table tab that lists the IP address for each processor. If these IP addresses must be changed during startup, then it will be necessary to also change the IP addresses in the Remote System Definition in the configuration file 58 +** See the[[ CoAP Setup Guide for details>>doc:SHOWRUNNER™ Integrations Guide.Integration Options.CoAP with Crestron S# Library and Modules.CoAP ShowRunner to ShowRunner Setup Instructions.WebHome]] 59 + 60 +=== Program Load === 61 + 62 +* Download the latest build of SHOWRUNNER™ [[https:~~/~~/files.chiefintegrations.com/s/WHNzXrrZbB5jC3E>>url:https://files.chiefintegrations.com/s/WHNzXrrZbB5jC3E]] 56 56 * Connect your computer to the same network as the processor. Make sure your computer’s IP settings are compatible with the lighting network and do not conflict with any devices already on the network. 57 57 * Double click the PUF to open the Package Update Tool and install SHOWRUNNER™ (works best with Toolbox closed) 58 -** The Package Update Tool will automatically open your Address Book 59 -* Select the PUF file again if needed, connect to the processor using the pencil, and select Recheck (This verifies the need to install the program, the XPanel UI, and the Crestron App UI) 60 -* Click Update when prompted to install ShowRunner 61 -* After loading, you can connect to the UI by navigating to the processor’s IP. 65 +** The Package Update Tool will automatically open your Address Book and prompt you to select a device 66 +*** If you have not created an Address Book for this job, close the Address Book window and press the pencil icon 67 +*** Type in the IP address of your processor and click "OK" 68 +** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target" 69 +** Press the "Recheck" button 70 +** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel") 71 +** Press the "Update" button to begin loading SHOWRUNNER™ 72 +* Sometimes the PUF tool will falsely report a failure to load the program 73 +** Connect to the processor via Text Console 74 +** Run the command ##sr ver## 75 +** If the console returns with the newly installed version of SHOWRUNNER™, then the installation was successful 76 +** If the console returns with "Bad or Incomplete Command (sr)" then the installation was not successful 77 +*** Right click on the PUF file and open the archive with your file archiver of choice (e.g. 7-Zip) 78 +*** Extract the "CI.Lighting.ShowRunner.cpz" file 79 +*** In Toolbox, connect to the processor via Text Console and click the lightning bolt icon and select "SIMPL Program..." 80 +*** Under the "Send" section, browse your PC and select the extracted .cpz file 81 +*** Click the "Send" button and click "Yes" to upload the program 82 +*** Once it is done loading, you should be able to run the ##sr ver## command and see the currently installed version of SHOWRUNNER™ 83 +* Once SHOWRUNNER™ is loaded, you can connect to the UI by navigating to the processor’s IP. A license and configuration file are still required. 62 62 ** **3-Series processors require authentication enabled** (SSL self can be used but steps will need to be repeated). 63 63 ** If stuck on "Connecting to Processor" you will need to accept the certificate. 64 -* Showrunner™will be loadedbuta configurationandlicensearetill needed.Pleaseproceedwiththenextsection.86 +* For jobs with multiple processors, SHOWRUNNER™ will need to be loaded to each processor. 65 65 66 66 === License and Configuration Deployment === 67 67 68 -* Download the configuration file from the link provided by Chief Integrations 90 +* Download the SrConfig.json or CiLightingConfig.json configuration file from the link provided by Chief Integrations 69 69 * Obtain and download the license from [[https:~~/~~/portal.chiefintegrations.com>>url:https://portal.chiefintegrations.com]] 70 70 ** Processors with a Control Subnet should use the LAN MAC address, **not** the Control Subnet MAC address 71 -* Navigate to the showrunner™ management page 72 -* Login to the showrunnerHUB™ 73 -** 4-Series processor: The login created by the processor will work 74 -** 3-Series processor: Using Toolbox Text Console - type "sradmin [username] [name] administrators [password]" (not needed if processor authentication is setup) 75 -* Click Setup then File Management 76 -** [[image:MicrosoftTeams-image7c355557d0a3ae410e72498ee667de2df50226f3e3940c2df4b51bb7137e176b.png||height="240" width="250"]] 77 -** Under “Upload New License File” 78 -*** Leave restart unchecked after transfer 79 -*** Select “Choose File” find the license file you downloaded from the portal 80 -*** Select “Upload” 81 -** Loading Configuration 82 -*** From Configuration File 83 -**** Under “Upload New Config File” 84 -***** Select “Choose File” and find the provided SrConfig.json for this processor from the project link that was sent at project delivery. 93 +* The license and configuration can be loaded with Toolbox using Text Console and File Management, or through the showrunnerHUB™ web interface 94 +** Using Toolbox: 95 +*** Connect to the processor via Text Console and via File Management 96 +*** In File management, navigate to the "NVRAM>sr" folder from the left-hand menu 97 +*** Right-click on the right-hand side and select "Copy File(s) From..." and select the downloaded License.lic file 98 +**** Alternatively, drag and drop the file from your computer to the File Management tool 99 +*** Using the left-hand menu, navigate to the "NVRAM>sr>default" folder 100 +*** Right-click on the right-hand side and select "Copy File(s) From..." and select the downloaded SrConfig.json file 101 +**** Alternatively, drag and drop the file from your computer to the File Management tool 102 +**** If you downloaded a CiLightingConfig.json file, it must be renamed to "SrConfig.json" 103 +** Using the showrunnerHUB™ UI: 104 +*** Using Chrome or Firefox, navigate to the processor's IP address 105 +*** When prompted, input your credentials and log in 106 +**** 4-Series processor or 3-Series processor with authentication enabled: Log in using the same admin credentials used to connect to the processor 107 +**** 3-Series processor without authentication enabled: Connect to the processor via Text Console and run the following command, replacing the "username", "name" and "password" with your desired credentials. 108 +***** ##sradmin username "name" administrators password## 109 +***** The username and password should be one word each and are the credentials used to log in to the showrunnerHUB™ 110 +***** The name can be multiple words as long as it is in quotes, and is simply a friendly name used to identify each user. 111 +*** Once logged in to the showrunnerHUB™ UI, you should be automatically redirected to the File Management page. 112 +**** If you are not automatically redirected, then you can navigate to this page by clicking "Setup" in the top right and then selecting "File Management" from the list on the left 113 +**** [[image:1654807593390-193.png]] 114 +**** Under “Upload New License File” 115 +***** Leave "Restart after transfer" unchecked 116 +***** Select “Choose File” and browse for the license file you downloaded from the portal 85 85 ***** Select “Upload” 86 -***** Alternatively, you can drop the License.lic using Toolbox’s File Manager or your SFTP client into the NVRAM/sr folder of the processor, the SrConfig.json into NVRAM/sr/default and perform “progreset” from the processor’s console 87 -***** The program will restart 88 -*** From Backup 89 -**** Select "Restore" 90 -**** Select "Choose Backup" and find the "SRBackup.zip" of the backup you wish to restore 91 -**** Enter the secret used to create the backup. Showrunner will upload the file and verify the secret. 92 -**** Select "Restart" to load the new configuration 93 -** Wait about 45 seconds after loading the configuration for the program to restart completely((( 94 - 95 -))) 118 +**** Load the configuration file either directly (if you have an SrConfig.json file) or from a backup (if you have an SRBackup.zip) 119 +***** Direct upload: 120 +****** Under “Upload New Config File” 121 +****** Select “Choose File” and find the provided CiLightingConfig.json or SrConfig.json file for this processor from the project link that was sent at project delivery. 122 +****** Select “Upload” 123 +***** From a Backup: 124 +****** Select "Restore" 125 +****** Select "Choose Backup" and find the SRBackup.zip of the backup you wish to restore 126 +****** Enter the secret used to create the backup. ShowRunner will upload the file and verify the secret. 127 +**** Once both the license and either a configuration file or backup have been loaded, click "Restart" 128 +**** Wait for the processor to finish restarting and then reload the page. 129 +***** 3-Series processors will take 45 to 90 restart 130 +***** 4-Series processors should restart considerably faster