Changes for page Processor Setup
                  Last modified by Alexander Mott on 2025/04/30 15:55
              
      
      From version  55.1 
    
    
              edited by Alexander Mott
        
on 2024/12/02 19:00
     on 2024/12/02 19:00
      Change comment:
              There is no comment for this version
          
         
      To version  52.1 
    
    
              edited by Alexander Mott
        
on 2024/03/27 15:23
     on 2024/03/27 15:23
      Change comment:
              There is no comment for this version
          
         Summary
- 
          Page properties (1 modified, 0 added, 0 removed)
 
Details
- Page properties
 - 
      
- Content
 -   
... ... @@ -1,11 +1,7 @@ 1 -(% class="box infomessage" %)1 +(% class="box errormessage" %) 2 2 ((( 3 3 This page is for typical processor setup; for ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]]. 4 4 ))) 5 -(% class="box errormessage" %) 6 -((( 7 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to factory reset the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. ** 8 -))) 9 9 10 10 (% class="box warningmessage" %) 11 11 ((( ... ... @@ -105,14 +105,6 @@ 105 105 ** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target" 106 106 ** Press the "Recheck" button 107 107 ** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel") 108 -** Additional tasks are available for certain processors: 109 -*** ZUM-HUB4: 110 -**** "Configure ZUM-HUB4" will automatically run commands: ##cwsanticsrf OFF## and ##startprogafterrouter on## 111 -**** "Configure ZUM-HUB4 Subnet" will automatically reconfigure the control subnet to a 100.64.0.0/20 configuration to avoid potential conflicts with corporate networks 112 -***** **NOTE: If you are connected to the Control Subnet and select this option, you will need to reconnect to the processor and run the .puf again in order to finish loading ShowRunnerCLC™ as this option will interrupt your connection to the processor.** 113 -**** "Configure ZUM-HUB4 SecureGateway" will automatically run command: ##securegateway default## 114 -*** Processors with Routers (AV3, CP3N, PRO3, AV4, CP4N, and PRO4) 115 -**** "Configure Processor with Router" will automatically run command: ##startprogafterrouter on## 116 116 ** Press the "Update" button to begin loading ShowRunnerCLC™ 117 117 * Sometimes the PUF tool will falsely report a failure to load the program 118 118 ** Connect to the processor via Text Console