1 1  (% class="box errormessage" %)
2 2  (((
3 3  This page is for typical processor setup; for ZUM-HUB4 deployments, see our [[dedicated ZUM-HUB4 page>>doc:SHOWRUNNER™ Setup Guide.SHOWRUNNER™ Installation Guide.SHOWRUNNER™ Installation and Network Setup.ZUM-HUB4 Processor Setup.WebHome]].
4 -
5 -All 4-Series processors require authentication to be configured when first connecting: **the Crestron Agent or Field Tech are responsible for recording these credentials. Chief Integrations cannot provide assistance unless the credentials are known. The only way to connect to a device for which the credentials have been lost is to factory reset the device, which may require redoing the start-up from scratch if the latest configuration was not saved and backed up. **
6 6  )))
7 7  
8 8  (% class="box warningmessage" %)
... ... @@ -103,14 +103,6 @@
103 103  ** Double check that the correct PUF file is listed under the "Package Info" section and that the correct IP address is listed under "Target"
104 104  ** Press the "Recheck" button
105 105  ** Make sure that all three tasks are selected ("Load ShowRunner Program", "Update Crestron App", and "Update XPanel")
106 -** Additional tasks are available for certain processors:
107 -*** ZUM-HUB4:
108 -**** "Configure ZUM-HUB4" will automatically run commands: ##cwsanticsrf OFF## and ##startprogafterrouter on##
109 -**** "Configure ZUM-HUB4 Subnet" will automatically reconfigure the control subnet to a 100.64.0.0/20 configuration to avoid potential conflicts with corporate networks
110 -***** **NOTE: If you are connected to the Control Subnet and select this option, you will need to reconnect to the processor and run the .puf again in order to finish loading ShowRunnerCLC™ as this option will interrupt your connection to the processor.**
111 -**** "Configure ZUM-HUB4 SecureGateway" will automatically run command: ##securegateway default##
112 -*** Processors with Routers (AV3, CP3N, PRO3, AV4, CP4N, and PRO4)
113 -**** "Configure Processor with Router" will automatically run command: ##startprogafterrouter on##
114 114  ** Press the "Update" button to begin loading ShowRunnerCLC™
115 115  * Sometimes the PUF tool will falsely report a failure to load the program
116 116  ** Connect to the processor via Text Console